Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/24623
Τίτλος: | Pile configuration optimization on the design of combined piled raft foundations | Συγγραφείς: | Asefa, Birhanu Assefa, Eleyas Pantelidis, Lysandros Sachpazis, Costas |
Major Field of Science: | Engineering and Technology | Field Category: | Civil Engineering | Λέξεις-κλειδιά: | FLAC3D;Interface elements;Numerical modeling;Pile configurations;Piled-raft foundation | Ημερομηνία Έκδοσης: | 2021 | Πηγή: | Modeling Earth Systems and Environment, 2021 | Περιοδικό: | Modeling Earth Systems and Environment | Περίληψη: | This paper examines the impact of different pile configurations and geometric parameters on the bearing capacity and the settlement response of a combined pile–raft foundation system utilizing FLAC3D software. The configurations considered were: (1) uniform piles (denoted as CONF1), (2) shorter and longer piles uniformly distributed on the plan view of the raft (CONF2), (3) shorter piles at the center and longer piles at the edge of the raft (CONF3), and (4) longer piles at the center and shorter piles at the edge of the raft (CONF4). In the same framework, different pile diameters and raft stiffnesses were examined. The piles are considered to float in a cohesive–frictional soil mass, simulating the thick cohesive soil deposit found in Addis Abeba (Ethiopia). During simulation, a zero-thickness interface element was employed to incorporate the complex interaction between the soil elements and the structural elements. The analyses indicate that the configuration of piles has a considerable effect on both the bearing capacity and the settlement response of the foundation system. CONF1 and CONF3 improve the bearing capacity and exhibits a smaller average settlement than other configurations. However, CONF3 registers the highest differential settlement. On the other hand, the lowest differential settlement was achieved by the CONF4 configuration; the same configuration also gives ultimate load resistance comparable to those provided by either CONF1 or CONF3. The study also showed that applying zero-thickness interface elements to simulate the interaction between components of the foundation system is suitable for examining piled raft foundations problem. | URI: | https://hdl.handle.net/20.500.14279/24623 | ISSN: | 23636203 | DOI: | 10.1007/s40808-021-01318-x | Rights: | © The Author(s) | Type: | Article | Affiliation: | Wollo University Addis Abeba Science and Technology University Cyprus University of Technology University of Western Macedonia |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
50
1
checked on 14 Μαρ 2024
WEB OF SCIENCETM
Citations
1
Last Week
0
0
Last month
0
0
checked on 1 Νοε 2023
Page view(s) 50
284
Last Week
2
2
Last month
3
3
checked on 29 Ιαν 2025
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons