Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/24408
Τίτλος: Automatic generation control of multi-source interconnected power system using FOI-TD controller
Συγγραφείς: Daraz, Amil 
Malik, Suheel Abdullah 
Waseem, Athar 
Azar, Ahmad Taher 
Haq, Ihsan Ul 
Ullah, Zahid 
Aslam, Sheraz 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Automatic generation control;Fractional order controller;Interconnected power system;Load frequency control;Optimization techniques
Ημερομηνία Έκδοσης: 1-Σεπ-2021
Πηγή: Energies, 2021, vol. 14, no. 18, articl. no. 5867
Volume: 14
Issue: 18
Περιοδικό: Energies 
Περίληψη: Automatic Generation Control (AGC) delivers a high quality electrical energy to energy consumers using efficient and intelligent control systems ensuring nominal operating frequency and organized tie-line power deviation. Subsequently, for the AGC analysis of a two-area interconnected hydro-gas-thermal-wind generating unit, a novel Fractional Order Integral-Tilt Derivative (FOI-TD) controller is proposed that is fine-tuned by a powerful meta-heuristic optimization technique referred as Improved-Fitness Dependent Optimizer (I-FDO) algorithm. For more realistic analysis, various constraints, such as Boiler Dynamics (BD), Time Delay (TD), Generation Rate Constraint (GRC), and Governor Dead Zone (GDZ) having non-linear features are incorporated in the specified system model. Moreover, a comparative analysis of I-FDO algorithm is performed with state-of-the-art approaches, such as FDO, teaching learning based optimization, and particle swarm optimization algorithms. Further, the proposed I-FDO tuned controller is compared with Fractional Order Tilt Integral Derivative (FOTID), PID, and Integral-Tilt Derivative (I-TD) controllers. The performance analysis demonstrates that proposed FOI-TD controller provides better performance and show strong robustness by changing system parameters and load condition in the range of  ± 50%, compared to other controllers.
URI: https://hdl.handle.net/20.500.14279/24408
ISSN: 19961073
DOI: 10.3390/en14185867
Rights: © The Author(s)
Type: Article
Affiliation: International Islamic University 
Prince Sultan University 
Benha University 
University of Management and Technology Lahore 
Cyprus University of Technology 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
energies-14-05867.pdf964.78 kBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

33
checked on 14 Μαρ 2024

WEB OF SCIENCETM
Citations

19
Last Week
0
Last month
3
checked on 29 Οκτ 2023

Page view(s)

337
Last Week
0
Last month
34
checked on 14 Μαρ 2025

Download(s)

162
checked on 14 Μαρ 2025

Google ScholarTM

Check

Altmetric


Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons Creative Commons