Τίτλος: | A Comparative Environmental Impact Study of Ground Source Heat Pump Systems | Συγγραφείς: | Aresti, Lazaros Christodoulides, Paul Makarounas, Christos Lazari, Lazaros Florides, Georgios A. |
Major Field of Science: | Engineering and Technology | Field Category: | Electrical Engineering - Electronic Engineering - Information Engineering | Λέξεις-κλειδιά: | Environmental impact;Life Cycle Analysis;Ground Source Heat Pumps;Geothermal Energy | Ημερομηνία Έκδοσης: | 2021 | Πηγή: | 8th International Conference on "Energy, Sustainability and Climate Crisis", Volos, Greece, August 30 - September 3, 2021 | Conference: | 8th International Conference on "Energy, Sustainability and Climate Crisis" | Περίληψη: | Ground Source Heat Pump (GSHP) systems are the main application of Shallow Geothermal Energy (SGE) systems, which are categorized as a RES. The GSHP systems consist of ground heat exchangers (GHEs) and HPs and they are used for space heating and cooling, exploiting Geothermal Energy. An important feature of RES is whether they are also “green” or ecological. Hence, this study focuses on the ecological aspect of GSHP systems, examining case studies in Cyprus and other European countries for residential buildings with high and low heating and cooling loads. The ground thermal characteristics and the peak heating and cooling loads of specific residential buildings of constant area are first used to determine the GHE length and the GSHP Coefficient of Performance (COP) by the GLD software. Next, a Life Cycle Analysis (LCA) of the systems is employed to estimate the environmental impact of all cases. The yearly heating and cooling load of the building is set as a functional unit, with the system boundaries containing the GHEs manufacturing and the operation of the system. An Air Source Heat Pump (ASHP) system is set as the baseline. The GSHP systems are compared to the baseline in percentage deviation, as, although the GSHP system is of higher COP than ASHP systems, it is not necessarily a more environmental-friendly solution in all cases. The LCA comparative results indicate that the location of the installed GSHP system play an important role in the magnitude of its environmental impact. | URI: | https://hdl.handle.net/20.500.14279/23743 | Rights: | Attribution-NonCommercial-NoDerivatives 4.0 International | Type: | Conference Papers | Affiliation: | Cyprus University of Technology |
Εμφανίζεται στις συλλογές: | Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
2021 Aresti et al. ESCC.pdf | 238.72 kB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
Page view(s)
224
Last Week
1
1
Last month
7
7
checked on 13 Μαϊ 2024
Download(s) 50
52
checked on 13 Μαϊ 2024
Google ScholarTM
Check
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons