Title: A Comparative Environmental Impact Study of Ground Source Heat Pump Systems
Authors: Aresti, Lazaros 
Christodoulides, Paul 
Makarounas, Christos 
Lazari, Lazaros 
Florides, Georgios A. 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Keywords: Environmental impact;Life Cycle Analysis;Ground Source Heat Pumps;Geothermal Energy
Issue Date: 2021
Source: 8th International Conference on "Energy, Sustainability and Climate Crisis", Volos, Greece, August 30 - September 3, 2021
Conference: 8th International Conference on "Energy, Sustainability and Climate Crisis" 
Abstract: Ground Source Heat Pump (GSHP) systems are the main application of Shallow Geothermal Energy (SGE) systems, which are categorized as a RES. The GSHP systems consist of ground heat exchangers (GHEs) and HPs and they are used for space heating and cooling, exploiting Geothermal Energy. An important feature of RES is whether they are also “green” or ecological. Hence, this study focuses on the ecological aspect of GSHP systems, examining case studies in Cyprus and other European countries for residential buildings with high and low heating and cooling loads. The ground thermal characteristics and the peak heating and cooling loads of specific residential buildings of constant area are first used to determine the GHE length and the GSHP Coefficient of Performance (COP) by the GLD software. Next, a Life Cycle Analysis (LCA) of the systems is employed to estimate the environmental impact of all cases. The yearly heating and cooling load of the building is set as a functional unit, with the system boundaries containing the GHEs manufacturing and the operation of the system. An Air Source Heat Pump (ASHP) system is set as the baseline. The GSHP systems are compared to the baseline in percentage deviation, as, although the GSHP system is of higher COP than ASHP systems, it is not necessarily a more environmental-friendly solution in all cases. The LCA comparative results indicate that the location of the installed GSHP system play an important role in the magnitude of its environmental impact.
URI: https://hdl.handle.net/20.500.14279/23743
Rights: Attribution-NonCommercial-NoDerivatives 4.0 International
Type: Conference Papers
Affiliation : Cyprus University of Technology 
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

Files in This Item:
File Description SizeFormat
2021 Aresti et al. ESCC.pdf238.72 kBAdobe PDFView/Open
CORE Recommender
Show full item record

Page view(s) 50

261
Last Week
3
Last month
5
checked on Nov 21, 2024

Download(s) 50

82
checked on Nov 21, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons