Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/23642
Title: Snakes based segmentation of the common carotid artery intima media
Authors: Loizou, Christos P. 
Pattichis, Constantinos S. 
Pantziaris, Marios 
Tyllis, Theodosis H. 
Nicolaides, Andrew N. 
Major Field of Science: Engineering and Technology
Field Category: Medical Engineering
Keywords: Snakes;Ultrasound imaging;Speckle reduction filtering;Normalization;Carotid artery;Intima media thickness
Issue Date: Jan-2007
Source: Medical & Biological Engineering & Computing , 2007, vol. 45, no. 1, pp. 35-49
Volume: 45
Issue: 1
Start page: 35
End page: 49
Journal: Medical & Biological Engineering & Computing 
Abstract: Ultrasound measurements of the human carotid artery walls are conventionally obtained by manually tracing interfaces between tissue layers. In this study we present a snakes segmentation technique for detecting the intima-media layer of the far wall of the common carotid artery (CCA) in longitudinal ultrasound images, by applying snakes, after normalization, speckle reduction, and normalization and speckle reduction. The proposed technique utilizes an improved snake initialization method, and an improved validation of the segmentation method. We have tested and clinically validated the segmentation technique on 100 longitudinal ultrasound images of the carotid artery based on manual measurements by two vascular experts, and a set of different evaluation criteria based on statistical measures and univariate statistical analysis. The results showed that there was no significant difference between all the snakes segmentation measurements and the manual measurements. For the normalized despeckled images, better snakes segmentation results with an intra-observer error of 0.08, a coefficient of variation of 12.5%, best Bland-Altman plot with smaller differences between experts (0.01, 0.09 for Expert1 and Expert 2, respectively), and a Hausdorff distance of 5.2, were obtained. Therefore, the pre-processing of ultrasound images of the carotid artery with normalization and speckle reduction, followed by the snakes segmentation algorithm can be used successfully in the measurement of IMT complementing the manual measurements. The present results are an expansion of data published earlier as an extended abstract in IFMBE Proceedings (Loizou et al. IEEE Int X Mediterr Conf Medicon Med Biol Eng POS-03 499:1-4, 2004).
URI: https://hdl.handle.net/20.500.14279/23642
ISSN: 17410444
DOI: 10.1007/s11517-006-0140-3
Rights: © Springer
Type: Article
Affiliation : Intercollege 
University of Cyprus 
Cyprus Institute of Neurology and Genetics 
Imperial College London 
Saint Mary’s Hospital 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

SCOPUSTM   
Citations

201
checked on Feb 2, 2024

WEB OF SCIENCETM
Citations

178
Last Week
0
Last month
1
checked on Oct 29, 2023

Page view(s)

554
Last Week
7
Last month
29
checked on Nov 21, 2024

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons