Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/23642
Title: | Snakes based segmentation of the common carotid artery intima media | Authors: | Loizou, Christos P. Pattichis, Constantinos S. Pantziaris, Marios Tyllis, Theodosis H. Nicolaides, Andrew N. |
Major Field of Science: | Engineering and Technology | Field Category: | Medical Engineering | Keywords: | Snakes;Ultrasound imaging;Speckle reduction filtering;Normalization;Carotid artery;Intima media thickness | Issue Date: | Jan-2007 | Source: | Medical & Biological Engineering & Computing , 2007, vol. 45, no. 1, pp. 35-49 | Volume: | 45 | Issue: | 1 | Start page: | 35 | End page: | 49 | Journal: | Medical & Biological Engineering & Computing | Abstract: | Ultrasound measurements of the human carotid artery walls are conventionally obtained by manually tracing interfaces between tissue layers. In this study we present a snakes segmentation technique for detecting the intima-media layer of the far wall of the common carotid artery (CCA) in longitudinal ultrasound images, by applying snakes, after normalization, speckle reduction, and normalization and speckle reduction. The proposed technique utilizes an improved snake initialization method, and an improved validation of the segmentation method. We have tested and clinically validated the segmentation technique on 100 longitudinal ultrasound images of the carotid artery based on manual measurements by two vascular experts, and a set of different evaluation criteria based on statistical measures and univariate statistical analysis. The results showed that there was no significant difference between all the snakes segmentation measurements and the manual measurements. For the normalized despeckled images, better snakes segmentation results with an intra-observer error of 0.08, a coefficient of variation of 12.5%, best Bland-Altman plot with smaller differences between experts (0.01, 0.09 for Expert1 and Expert 2, respectively), and a Hausdorff distance of 5.2, were obtained. Therefore, the pre-processing of ultrasound images of the carotid artery with normalization and speckle reduction, followed by the snakes segmentation algorithm can be used successfully in the measurement of IMT complementing the manual measurements. The present results are an expansion of data published earlier as an extended abstract in IFMBE Proceedings (Loizou et al. IEEE Int X Mediterr Conf Medicon Med Biol Eng POS-03 499:1-4, 2004). | URI: | https://hdl.handle.net/20.500.14279/23642 | ISSN: | 17410444 | DOI: | 10.1007/s11517-006-0140-3 | Rights: | © Springer | Type: | Article | Affiliation : | Intercollege University of Cyprus Cyprus Institute of Neurology and Genetics Imperial College London Saint Mary’s Hospital |
Publication Type: | Peer Reviewed |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
201
checked on Feb 2, 2024
WEB OF SCIENCETM
Citations
178
Last Week
0
0
Last month
1
1
checked on Oct 29, 2023
Page view(s) 10
581
Last Week
7
7
Last month
27
27
checked on Dec 22, 2024
Google ScholarTM
Check
Altmetric
This item is licensed under a Creative Commons License