Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/23642
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Loizou, Christos P. | - |
dc.contributor.author | Pattichis, Constantinos S. | - |
dc.contributor.author | Pantziaris, Marios | - |
dc.contributor.author | Tyllis, Theodosis H. | - |
dc.contributor.author | Nicolaides, Andrew N. | - |
dc.date.accessioned | 2021-11-15T11:23:13Z | - |
dc.date.available | 2021-11-15T11:23:13Z | - |
dc.date.issued | 2007-01 | - |
dc.identifier.citation | Medical & Biological Engineering & Computing , 2007, vol. 45, no. 1, pp. 35-49 | en_US |
dc.identifier.issn | 17410444 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.14279/23642 | - |
dc.description.abstract | Ultrasound measurements of the human carotid artery walls are conventionally obtained by manually tracing interfaces between tissue layers. In this study we present a snakes segmentation technique for detecting the intima-media layer of the far wall of the common carotid artery (CCA) in longitudinal ultrasound images, by applying snakes, after normalization, speckle reduction, and normalization and speckle reduction. The proposed technique utilizes an improved snake initialization method, and an improved validation of the segmentation method. We have tested and clinically validated the segmentation technique on 100 longitudinal ultrasound images of the carotid artery based on manual measurements by two vascular experts, and a set of different evaluation criteria based on statistical measures and univariate statistical analysis. The results showed that there was no significant difference between all the snakes segmentation measurements and the manual measurements. For the normalized despeckled images, better snakes segmentation results with an intra-observer error of 0.08, a coefficient of variation of 12.5%, best Bland-Altman plot with smaller differences between experts (0.01, 0.09 for Expert1 and Expert 2, respectively), and a Hausdorff distance of 5.2, were obtained. Therefore, the pre-processing of ultrasound images of the carotid artery with normalization and speckle reduction, followed by the snakes segmentation algorithm can be used successfully in the measurement of IMT complementing the manual measurements. The present results are an expansion of data published earlier as an extended abstract in IFMBE Proceedings (Loizou et al. IEEE Int X Mediterr Conf Medicon Med Biol Eng POS-03 499:1-4, 2004). | en_US |
dc.format | en_US | |
dc.language.iso | en | en_US |
dc.relation.ispartof | Medical & Biological Engineering & Computing | en_US |
dc.rights | © Springer | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Snakes | en_US |
dc.subject | Ultrasound imaging | en_US |
dc.subject | Speckle reduction filtering | en_US |
dc.subject | Normalization | en_US |
dc.subject | Carotid artery | en_US |
dc.subject | Intima media thickness | en_US |
dc.title | Snakes based segmentation of the common carotid artery intima media | en_US |
dc.type | Article | en_US |
dc.collaboration | Intercollege | en_US |
dc.collaboration | University of Cyprus | en_US |
dc.collaboration | Cyprus Institute of Neurology and Genetics | en_US |
dc.collaboration | Imperial College London | en_US |
dc.collaboration | Saint Mary’s Hospital | en_US |
dc.subject.category | Medical Engineering | en_US |
dc.journals | Subscription | en_US |
dc.country | Cyprus | en_US |
dc.country | United Kingdom | en_US |
dc.subject.field | Engineering and Technology | en_US |
dc.publication | Peer Reviewed | en_US |
dc.identifier.doi | 10.1007/s11517-006-0140-3 | en_US |
dc.identifier.pmid | 17203319 | - |
dc.identifier.scopus | 2-s2.0-33846418345 | - |
dc.identifier.url | https://api.elsevier.com/content/abstract/scopus_id/33846418345 | - |
dc.relation.issue | 1 | en_US |
dc.relation.volume | 45 | en_US |
cut.common.academicyear | 2006-2007 | en_US |
dc.identifier.spage | 35 | en_US |
dc.identifier.epage | 49 | en_US |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.openairetype | article | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | Department of Electrical Engineering, Computer Engineering and Informatics | - |
crisitem.author.faculty | Faculty of Engineering and Technology | - |
crisitem.author.orcid | 0000-0003-1247-8573 | - |
crisitem.author.parentorg | Faculty of Engineering and Technology | - |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
201
checked on Feb 2, 2024
WEB OF SCIENCETM
Citations
178
Last Week
0
0
Last month
1
1
checked on Oct 29, 2023
Page view(s)
630
Last Week
8
8
Last month
37
37
checked on Feb 3, 2025
Google ScholarTM
Check
Altmetric
This item is licensed under a Creative Commons License