Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/23596
Τίτλος: Segmentation of the common carotid intima-media complex in ultrasound images using active contours
Συγγραφείς: Petroudi, Styliani H. 
Loizou, Christos P. 
Pantziaris, Marios 
Pattichis, Constantinos S. 
Major Field of Science: Engineering and Technology
Field Category: Medical Engineering
Λέξεις-κλειδιά: Active contours;Carotid artery;Intima-media thickness;Level sets;Segmentation;Ultrasound imaging
Ημερομηνία Έκδοσης: Νοε-2012
Πηγή: IEEE Transactions on Biomedical Engineering, 2012, vol. 59, no. 11, pp. 3060-3069
Volume: 59
Issue: 11
Start page: 3060
End page: 3069
Περιοδικό: IEEE Transactions on Biomedical Engineering 
Περίληψη: The segmentation of the intima-media complex (IMC) of the common carotid artery (CCA) wall is important for the evaluation of the intima media thickness (IMT) on B-mode ultrasound (US) images. The IMT is considered an important marker in the evaluation of the risk for the development of atherosclerosis. The fully automated segmentation algorithm presented in this article is based on active contours and active contours without edges and incorporates anatomical information to achieve accurate segmentation. The level set formulation by Chan and Vese using random initialization provides a segmentation of the CCA US images into different distinct regions, one of which corresponds to the carotid wall region below the lumen and includes the far wall IMC. The segmented regions are used to automatically achieve image normalization, which is followed by speckle removal. The resulting smoothed lumen-intima boundary combined with anatomical information provide an excellent initialization for parametric active contours that provide the final IMC segmentation. The algorithm is extensively evaluated on 100 different cases with ground truth (GT) segmentation available from two expert clinicians. The GT mean IMT value is 0.6679 mm +/ - 0.1350 mm and the corresponding automatically segmented (AS) mean IMT value is 0.6054 mm +/ - 0.1464 mm. The mean absolute difference between the GT IMT and the IMT evaluated from from the AS region is 0.095 mm +/ - 0.0615 mm. The polyline distance is 0.096 mm +/ - 0.034 mm while the Hausdorff distance is 0.176 mm +/ - 0.047 mm. The algorithm compares favorably to both automatic and semiautomatic methods presented in the literature.
URI: https://hdl.handle.net/20.500.14279/23596
ISSN: 15582531
DOI: 10.1109/TBME.2012.2214387
Rights: © IEEE
Type: Article
Affiliation: University of Cyprus 
Intercollege 
Cyprus Institute of Neurology and Genetics 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

57
checked on 2 Φεβ 2024

WEB OF SCIENCETM
Citations

50
Last Week
0
Last month
2
checked on 29 Οκτ 2023

Page view(s)

224
Last Week
2
Last month
10
checked on 9 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons Creative Commons