Τίτλος: | Stochastic Unit Commitment in Low-Inertia Grids | Συγγραφείς: | Paturet, Matthieu Markovic, Uros Delikaraoglou, Stefanos Vrettos, Evangelos Aristidou, Petros Hug, Gabriela |
Major Field of Science: | Engineering and Technology | Field Category: | Electrical Engineering - Electronic Engineering - Information Engineering | Λέξεις-κλειδιά: | Unit commitment;Low-inertia grid;Frequency constraints;Wind uncertainty;Voltage source converter | Ημερομηνία Έκδοσης: | Σεπ-2020 | Πηγή: | IEEE Transactions on Power Systems, 2020, vol. 35, no. 5, pp. 3448 - 3458 | Volume: | 35 | Issue: | 5 | Start page: | 3448 | End page: | 3458 | Περιοδικό: | IEEE Transactions on Power Systems | Περίληψη: | In this paper, the Unit Commitment (UC) problem in a power network with low levels of rotational inertia is studied. Frequency-related constraints, namely the limitation on Rate-of-Change-of-Frequency (RoCoF), frequency nadir and steady-state frequency error, are derived from a uniform system frequency response model that incorporates dynamics and controls of both synchronous generators and grid-forming inverters. These constraints are then included into a stochastic UC formulation that accounts for wind power and equipment contingency uncertainties using a scenario-tree approach. In contrast to the linear RoCoF and steady-state frequency error constraints, the nadir constraint is highly nonlinear. To preserve the mixed-integer linear formulation of the stochastic UC model, we propose a computationally efficient approach that allows to recast the nadir constraint by introducing appropriate bounds on relevant decision variables of the UC model. This method is shown to be generally more accurate and computationally more efficient for medium-sized networks than a piece-wise linearization method adapted from the literature. Simulation results for a modified IEEE RTS-96 system revealed that the inclusion of inertia-related constraints significantly influences the UC decisions and increases total costs, as more synchronous machines are forced to be online to provide inertial response. | ISSN: | 08858950 | DOI: | 10.1109/tpwrs.2020.2987076 | Rights: | © IEEE | Type: | Article | Affiliation: | Cyprus University of Technology ETH Zurich Institute of Harvard and MIT |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
manuscript.pdf | 8.45 MB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
2
checked on 21 Μαρ 2021
WEB OF SCIENCETM
Citations
59
Last Week
1
1
Last month
1
1
checked on 29 Οκτ 2023
Page view(s) 50
356
Last Week
0
0
Last month
1
1
checked on 22 Δεκ 2024
Download(s)
234
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα