Τίτλος: A building integrated photovoltaic (BIPV) demonstration building in Belgium with new fibre reinforced solar technology PV modules: analysis with simulation and monitoring data
Συγγραφείς: Agathokleous, Rafaela 
Kalogirou, Soteris A. 
Pierret, Stéphane 
Major Field of Science: Engineering and Technology
Field Category: Mechanical Engineering
Λέξεις-κλειδιά: Building integrated PV;Fibre Reinforced Solar Technology PV;Simulation;Monitoring
Ημερομηνία Έκδοσης: Μαρ-2017
Πηγή: First International Conference on Building Integrated Renewable Energy Systems, 2017, 6-9 March, Dublin, Ireland
Conference: International Conference on Building Integrated Renewable Energy Systems 
Περίληψη: New more flexible and lightweight photovoltaic (PV) modules based on a novel encapsulation technology with glass fibre reinforced composite materials are installed in a residential building in Mons, Belgium which is used as a demonstration building. The tested modules are named roofing shingles (RS) and they are installed on the south part of the building’s roof with inclination angle 40⁰. The installation comprises of 54 RS modules of 32 monocrystalline Silicon cells each. The total installed power of the system is 7.01 kWp. The BIPV system installed on the Belgian demo site is monitored to observe its performance and optimise the installation in case of efficiency loss due to natural parameters e.g. overheating. Various equipment like temperature, humidity, radiation sensors, data loggers etc., are installed on the building for the monitoring. Prior to the installation, a simulation model in TRNSYS simulation software is carried out using weather data for Belgium from a Typical Meteorological Year (TMY) file, to predict the performance of the system as well as other various parameters such as the developed temperature on the PVs surface, air gap temperature etc. The aim of this study is to present the performance of the BIPV system on the demo site and compare the monitoring data with the simulation results. It is concluded that the results from the simulation agree with the monitoring results measured on site.
URI: https://hdl.handle.net/20.500.14279/18265
Type: Conference Papers
Affiliation: Cyprus University of Technology 
Optimal Computing 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
Kalogirou.pdfFulltext1.02 MBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

Page view(s) 50

358
Last Week
0
Last month
6
checked on 22 Δεκ 2024

Download(s) 20

149
checked on 22 Δεκ 2024

Google ScholarTM

Check


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα