Τίτλος: Thermal Analysis of a Building Integrated Photovoltaic (BIPV) System
Συγγραφείς: Agathokleous, Rafaela 
Kalogirou, Soteris A. 
Major Field of Science: Engineering and Technology
Field Category: Environmental Engineering
Λέξεις-κλειδιά: Solar simulator;BIPV;Integration;Thermal behaviour;Photovoltaics;BIPV/T
Ημερομηνία Έκδοσης: Ιου-2016
Πηγή: 29th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, 2016, 19-23 June, Portoroz, Slovenia
Conference: 29th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems 
Περίληψη: During the last few years photovoltaic (PV) panels are increasingly incorporated into the construction of buildings for generating electrical power (BIPV systems) or both electrical and thermal energy (BIPV/T systems). The integration creates heat in the gap between the PVs and the building’s skin, which if not removed to be used to cover part of the heating load of the building (winter) or to the atmosphere (summer), it decreases the efficiency of the PVs and increases the cooling loads of the buildings in summertime. This study aims to evaluate the thermal behaviour of a BIPV system in order to decide whether natural ventilation of the air behind the PV is adequate to cool it down and remove the excess heat. The examination of the effect of the air gap of a BIPV system as well as the slope of the system or the amount of solar radiation are very important parameters as they can lead to better understanding of the conditions that allow the higher efficiency of the PV panels and accordingly higher efficiency of the BIPV system. The investigation of the above parameters is done experimentally in a laboratory with a large scale solar simulator (SS) and a representative apparatus of a BIPV system, able to change the air gap of the duct and the slope in order to simulate roof or façade installation. The experimental results are compared with 3D modelling simulation results obtained using COMSOL Multiphysics software.
URI: https://hdl.handle.net/20.500.14279/18264
Type: Conference Papers
Affiliation: Cyprus University of Technology 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
Kalogirou.pdfFulltext1.19 MBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

Page view(s) 50

378
Last Week
1
Last month
11
checked on 5 Ιαν 2025

Download(s) 50

169
checked on 5 Ιαν 2025

Google ScholarTM

Check


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα