Title: | Performance characteristics of automated clinical chemistry analyzers using commercial assay reagents contributing to quality assurance and clinical decision in a hospital laboratory | Authors: | Tzortzopoulos, Athanasios Raftopoulos, Vasilios Talias, Michael A. |
Major Field of Science: | Medical and Health Sciences | Field Category: | Clinical Medicine | Keywords: | Clinical chemistry;Clinical decision;Evaluation;Sigma metrics;Uncertainty;Validation studies | Issue Date: | 2-Jan-2020 | Source: | Scandinavian Journal of Clinical and Laboratory Investigation, 2020, vol. 80, no. 1, pp. 46-54 | Volume: | 80 | Issue: | 1 | Start page: | 46 | End page: | 54 | Journal: | Scandinavian Journal of Clinical and Laboratory Investigation | Abstract: | Background: Clinical laboratories provide essential diagnostic services that are essential in clinical decision making, contributing to the quality of healthcare. The performance of two Siemens ADVIA 1800 analyzers was characterized in a hospital Biochemistry laboratory in order to evaluate the analytical characteristics of such automated analyzer systems using nonoriginal assay reagents attempting to support laboratory quality service and crucial clinical decision making. Methods: We independently completed performance validation studies including trueness, precision, sensitivity as well as measurement of uncertainty and sigma metrics calculation for 25 biochemical parameters. Results: Trueness expressed as bias was less than 20% for both ADVIA 1800 analyzers. Within run and total precisions expressed as CV% were ≤9.85% on both analyzers for most parameters studied with few exceptions (Mg, TB, DB, Cl, HDL and UA) observed either in low or in high level samples and between the two analyzers. LoB, LoD and LoQ values produced by the two analyzers were comparable except Cl. Uncertainty values produced by the two analyzers were comparable with no significant differences. Quality performance of reagent assays was studied using the sigma metrics system. The sigma values were plotted on normalized method decision charts for graphical representation of assay performances for each analyzer. Conclusions: The two ADVIA systems, independently evaluated, showed consistent performance characteristics with certain discrepancies by several reagents. Sigma analysis was helpful for revealing the quality performance of non-original reagents supporting the need for strict assessment of quality assurance and in some instances optimization/improvement of assay methods. | ISSN: | 15027686 | DOI: | 10.1080/00365513.2019.1695282 | Rights: | © Medisinsk Fysiologisk Forenings Forlag (MFFF) | Type: | Article | Affiliation : | Cyprus University of Technology General Hospital of Agrinio Aghia Sophia Children's Hospital Open University Cyprus |
Publication Type: | Peer Reviewed |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
2
checked on Feb 1, 2024
WEB OF SCIENCETM
Citations
1
Last Week
0
0
Last month
0
0
checked on Oct 29, 2023
Page view(s) 50
370
Last Week
2
2
Last month
7
7
checked on Dec 22, 2024
Google ScholarTM
Check
Altmetric
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.