Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/1758
Τίτλος: Analysis of the proximal orifice flowfield under pulsatile flow conditions and confining wall geometry: implications in valvular regurgitation
Συγγραφείς: Fan, Pohoey 
Perry, Gilbert J. 
Anayiotos, Andreas 
metadata.dc.contributor.other: Αναγιωτός, Ανδρέας
Major Field of Science: Medical and Health Sciences
Λέξεις-κλειδιά: Hemodynamics;Computer simulation;Blood flow
Ημερομηνία Έκδοσης: 1998
Πηγή: Echocardiography, 1998, vol. 15, no. 3, pp. 219-232
Volume: 15
Issue: 3
Start page: 219
End page: 232
Περιοδικό: Echocardiography 
Περίληψη: Hemodynamic studies of regurgitant lesions in the heart focus on identifying a reliable noninvasive method of volumetric flow calculation. In these studies the influence of blood viscosity to the flowfield under pulsatile flow conditions and constraining wall geometry has not been examined in detail. Pulsatile flow studies in straight tubes have shown that viscous effects significantly influence the periodic flowfield, especially near the wall. The purpose of this study is to investigate the significance of transient effects in the flowfield proximal to a lesion under constraining wall geometry. The proximal flowfield was analyzed with computational fluid dynamics (CFD) computer simulations and color flow Doppler mapping (CFM). Three different stroke volumes and regurgitant waveforms were investigated for upstream wall orientations that varied from - 64°to + 64°(measured from the orifice plane). Results showed that for each upstream wall orientation, a single instantaneously normalized centerline velocity distribution characterized the flowfield throughout the cycle. The centerline distributions were in phase with the pressure gradient and almost identical to the corresponding steady-state distributions. Minor deviations were observed near the wall, where viscous effects were predominant. Transient flow effects such as blunt profiles and pressure velocity phase shifts, which were observed in straight circular tubes, were not observed in regurgitant orifice flowfields. This is true even under severe confinement conditions.
URI: https://hdl.handle.net/20.500.14279/1758
ISSN: 07422822
DOI: 10.1111/j.1540-8175.1998.tb00600.x
Rights: © Wiley
Type: Article
Affiliation: University of Alabama at Birmingham 
Affiliation: University of Alabama at Birmingham 
Birmingham Veteran's Administration Medical Center 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
analysisi of the proximal orifice flowfield under.pdf924.81 kBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

6
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations 50

3
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

486
Last Week
2
Last month
34
checked on 13 Μαρ 2025

Download(s) 20

144
checked on 13 Μαρ 2025

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα