Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/1736
Title: Energy analysis of buildings employing thermal mass in Cyprus
Authors: Florides, Georgios A. 
Tassou, Savvas A. 
Kalogirou, Soteris A. 
Florides, Georgios A. 
Major Field of Science: Engineering and Technology
Field Category: Environmental Engineering
Keywords: Energy analysis;Thermal mass;TRNSYS simulation program
Issue Date: Nov-2002
Source: Renewable Energy, Vol. 27, no. 3, 2002, pp. 353-368
Volume: 27
Issue: 3
Start page: 353
End page: 368
Journal: Renewable Energy 
Abstract: In this paper the effects on the heating and cooling load resulting from the use of building thermal mass in Cyprus are presented. This is achieved by modelling and simulation with the TRNSYS program of a typical four-zone building with an insulated roof in which the south wall of one of the zones has been replaced by a thermal wall. Despite the fact that the diurnal temperature variations in Cyprus are ideal for the application of thermal mass, no such application is presently available. Therefore the main objective of this paper is to investigate the possible benefits resulting from such an application. The results of the simulation show that there is a reduction in the heating load requirement of the zone by about 47%, whereas at the same time a slight increase of the zone-cooling load is exhibited. Optimisations of the various construction parameters have also been carried out. The optimum overhang size is found to be equal to 1.2 m with minor variations in the range of 1 to 1.5 m. The effect of the air gap size between the glazing and the thermal wall is insignificant. The optimum value of wall thickness obtained is equal to 25 cm. The effect of roof insulation is investigated and it is found that insulation is a must for better comfort conditions. Also, the effect of applying ventilation whenever the ambient temperature is lower than the indoor temperature during summertime is investigated. A reduction of 7.5% is obtained when air at 3 air changes per hour is directed into the house. In conclusion it can be said that the thermal wall offers some advantages and should be used whenever buildings are erected with south-facing walls.
URI: https://hdl.handle.net/20.500.14279/1736
ISSN: 09601481
DOI: 10.1016/S0960-1481(02)00007-1
Rights: © Elsevier 2002
Type: Article
Affiliation : Higher Technical Institute Cyprus 
Brunel University London 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

SCOPUSTM   
Citations

83
checked on Nov 9, 2023

WEB OF SCIENCETM
Citations 20

62
Last Week
0
Last month
0
checked on Oct 17, 2023

Page view(s)

492
Last Week
0
Last month
2
checked on Nov 21, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.