Title: | Energy analysis of buildings employing thermal mass in Cyprus | Authors: | Florides, Georgios A. Tassou, Savvas A. Kalogirou, Soteris A. Florides, Georgios A. |
Major Field of Science: | Engineering and Technology | Field Category: | Environmental Engineering | Keywords: | Energy analysis;Thermal mass;TRNSYS simulation program | Issue Date: | Nov-2002 | Source: | Renewable Energy, Vol. 27, no. 3, 2002, pp. 353-368 | Volume: | 27 | Issue: | 3 | Start page: | 353 | End page: | 368 | Journal: | Renewable Energy | Abstract: | In this paper the effects on the heating and cooling load resulting from the use of building thermal mass in Cyprus are presented. This is achieved by modelling and simulation with the TRNSYS program of a typical four-zone building with an insulated roof in which the south wall of one of the zones has been replaced by a thermal wall. Despite the fact that the diurnal temperature variations in Cyprus are ideal for the application of thermal mass, no such application is presently available. Therefore the main objective of this paper is to investigate the possible benefits resulting from such an application. The results of the simulation show that there is a reduction in the heating load requirement of the zone by about 47%, whereas at the same time a slight increase of the zone-cooling load is exhibited. Optimisations of the various construction parameters have also been carried out. The optimum overhang size is found to be equal to 1.2 m with minor variations in the range of 1 to 1.5 m. The effect of the air gap size between the glazing and the thermal wall is insignificant. The optimum value of wall thickness obtained is equal to 25 cm. The effect of roof insulation is investigated and it is found that insulation is a must for better comfort conditions. Also, the effect of applying ventilation whenever the ambient temperature is lower than the indoor temperature during summertime is investigated. A reduction of 7.5% is obtained when air at 3 air changes per hour is directed into the house. In conclusion it can be said that the thermal wall offers some advantages and should be used whenever buildings are erected with south-facing walls. | URI: | https://hdl.handle.net/20.500.14279/1736 | ISSN: | 09601481 | DOI: | 10.1016/S0960-1481(02)00007-1 | Rights: | © Elsevier 2002 | Type: | Article | Affiliation : | Higher Technical Institute Cyprus Brunel University London |
Publication Type: | Peer Reviewed |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
83
checked on Nov 9, 2023
WEB OF SCIENCETM
Citations
20
62
Last Week
0
0
Last month
0
0
checked on Oct 17, 2023
Page view(s) 20
494
Last Week
0
0
Last month
3
3
checked on Dec 22, 2024
Google ScholarTM
Check
Altmetric
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.