Rapid velocity-encoded cine imaging with turbo-BRISK

Journal
Journal of Cardiovascular Magnetic Resonance
Date Issued
1999
Author(s)
Doyle, Mark W.  
Kortright, Eduardo  
Anayiotos, Andreas  
Elmahdi, Abdelaziz M.  
Walsh, Edward G.  
Fuisz, Anthon  
Pohost, Gerald  
DOI
10.3109/10976649909088334
Abstract
Velocity-encoded cine (VEC) imaging is potentially an important clinical diagnostic technique for cardiovascular diseases. Advances in gradient technology combined with segmentation approaches have made possible breathhold VEC imaging, allowing data to be obtained free of respiratory artifacts. However, when using conventional segmentation approaches, spatial and temporal resolutions are typically compromised to accommodate short breathhold times. Here we apply a sparse sampling technique, turbo-BRISK (i.e., segmented block regional interpolation scheme for k-space) to VEC imaging, allowing increased spatial and temporal resolution to be obtained in a short breathhold period. BRISK is a sparse sampling technique with interpolation used to generate unsampled data. BRISK was implemented to reduce the scan time by 70% compared with a conventional scan. Further, turbo-BRISK scans, using segmentation factors up to 5, reduce the scan time by up to 94%. Phantom and in vivo results are presented that demonstrate the accuracy of turbo-BRISK VEC imaging. In vitro validation is performed using conventional magnetic resonance VEC. Pulsatile centerline flow velocity measurements obtained with turbo-BRISK acquisitions were correlated with conventional magnetic resonance imaging measurements and achieved r values of 0.99 +/- 0.004 (mean +/- SD) with stroke volumes agreeing to within 4%. A potential limitation of BRISK is reduced accuracy for rapidly varying velocity profiles. We present low- and high-resolution data sets to illustrate the resolution dependence of this phenomenon and demonstrate that at conventional resolutions, turbo-BRISK can accurately represent rapid velocity changes. In vivo results indicate that centerline velocity waveforms in the descending aorta correlate well with conventional measurements with an average r value of 0.98 +/- 0.01.
Subjects

Fast imaging

Flow

K-space

Vascular

VEC

Explore by
  • Collections
  • Research Outputs
  • Researchers
  • Faculty & Departments
  • Theses
  • Patents
  • Projects
  • Journals
  • Conferences
Useful Links
  • Researcher Portfolio Guide
  • Researcher Profile
  • Create an ORCID ID
  • CUT Open Access Author Fund
  • ETDS Guide
Copyright Policies

Use Sherpa/Romeo to find publisher copyright policies

Go
Go
  • SPARC Author Addendum Engine
  • National Open Access Policy in Cyprus
Deposit your work to Ktisis
  • Self-archiving. Please sign in to Ktisis.
  • Email your work to:
    library.dspace@cut.ac.cy
  • Contact your subject librarian

Member of

OpenAIREre3dataOpenDOARCOREDART
Cyprus University of Technology
Library and
Information
Services

Copyright © 2022 - Library and Information Services Feedback - Built with DSpace-CRIS - 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
COAR NotifyCOAR Notify