Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/16204
DC FieldValueLanguage
dc.contributor.authorDoyle, Mark W.-
dc.contributor.authorKortright, Eduardo-
dc.contributor.authorAnayiotos, Andreas-
dc.contributor.authorElmahdi, Abdelaziz M.-
dc.contributor.authorWalsh, Edward G.-
dc.contributor.authorFuisz, Anthon-
dc.contributor.authorPohost, Gerald-
dc.date.accessioned2020-02-18T12:27:51Z-
dc.date.available2020-02-18T12:27:51Z-
dc.date.issued1999-
dc.identifier.citationJournal of Cardiovascular Magnetic Resonance,1999, vol. 1, no. 3, pp. 223-232en_US
dc.identifier.issn10976647-
dc.identifier.urihttps://hdl.handle.net/20.500.14279/16204-
dc.description.abstractVelocity-encoded cine (VEC) imaging is potentially an important clinical diagnostic technique for cardiovascular diseases. Advances in gradient technology combined with segmentation approaches have made possible breathhold VEC imaging, allowing data to be obtained free of respiratory artifacts. However, when using conventional segmentation approaches, spatial and temporal resolutions are typically compromised to accommodate short breathhold times. Here we apply a sparse sampling technique, turbo-BRISK (i.e., segmented block regional interpolation scheme for k-space) to VEC imaging, allowing increased spatial and temporal resolution to be obtained in a short breathhold period. BRISK is a sparse sampling technique with interpolation used to generate unsampled data. BRISK was implemented to reduce the scan time by 70% compared with a conventional scan. Further, turbo-BRISK scans, using segmentation factors up to 5, reduce the scan time by up to 94%. Phantom and in vivo results are presented that demonstrate the accuracy of turbo-BRISK VEC imaging. In vitro validation is performed using conventional magnetic resonance VEC. Pulsatile centerline flow velocity measurements obtained with turbo-BRISK acquisitions were correlated with conventional magnetic resonance imaging measurements and achieved r values of 0.99 +/- 0.004 (mean +/- SD) with stroke volumes agreeing to within 4%. A potential limitation of BRISK is reduced accuracy for rapidly varying velocity profiles. We present low- and high-resolution data sets to illustrate the resolution dependence of this phenomenon and demonstrate that at conventional resolutions, turbo-BRISK can accurately represent rapid velocity changes. In vivo results indicate that centerline velocity waveforms in the descending aorta correlate well with conventional measurements with an average r value of 0.98 +/- 0.01.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.relation.ispartofJournal of Cardiovascular Magnetic Resonanceen_US
dc.rights© Elsevieren_US
dc.subjectFast imagingen_US
dc.subjectFlowen_US
dc.subjectK-spaceen_US
dc.subjectVascularen_US
dc.subjectVECen_US
dc.titleRapid velocity-encoded cine imaging with turbo-BRISKen_US
dc.typeArticleen_US
dc.collaborationUniversity of Alabama at Birminghamen_US
dc.subject.categoryMechanical Engineeringen_US
dc.journalsOpen Accessen_US
dc.countryCyprusen_US
dc.countryUnited Statesen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.identifier.doi10.3109/10976649909088334en_US
dc.identifier.pmid11550356-
dc.identifier.scopus2-s2.0-0033301657-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/0033301657-
dc.relation.issue3en_US
dc.relation.volume1en_US
cut.common.academicyear1998-1999en_US
dc.identifier.spage223en_US
dc.identifier.epage232en_US
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairetypearticle-
crisitem.journal.journalissn1532-429X-
crisitem.journal.publisherBioMed Central-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-4471-7604-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

SCOPUSTM   
Citations

11
checked on Feb 2, 2024

WEB OF SCIENCETM
Citations

7
Last Week
0
Last month
0
checked on Oct 29, 2023

Page view(s) 50

374
Last Week
1
Last month
1
checked on Dec 22, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.