Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/15745
Τίτλος: Performance investigation of a Ground Source Heat Pump system for space heating and cooling of a typical house in moderate climates
Συγγραφείς: Florides, Georgios A. 
Aresti, Lazaros 
Messaritis, Vassilios 
Christodoulides, Paul 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Energy Efficiency
Ημερομηνία Έκδοσης: 2019
Πηγή: 6th International Conference on Energy, Sustainability and Climate Change ESCC2019
Conference: International Conference on Energy Sustainability and Climate Change 
Περίληψη: Air Source Heat Pumps (ASHPs) are commonly used for the air-conditioning of buildings. They practically use the atmosphere as a heat source/sink to absorb/reject heat. A Renewable Energy System (RES) that exploits the ground to absorb/reject heat from the building is called Shallow Geothermal Energy System (SGES). The ground temperature is always lower in the summer and higher in winter compared to atmospheric air temperature. In such systems, the usual tool are Ground Source Heat Pumps (GSHPs) that are employed to further increase the heat pump efficiency and reduce the required electricity. The evolution of the SGEs has led to competition with the ASHPs and the manufacturing of custom designed inverter technology ducted series HPs. It has also initiated the debate whether it is economically feasible to install GHEs as an alternative to the custom designed HP. This study presents such a case with the introduction of a typical house in moderate climate (Cyprus weather conditions) by using an experimentally validated Computational Fluid Dynamics model. Different water inlet temperatures are examined for both summer and winter. The system efficiency is discussed in relation to the power rejected to the ground and the length of the GHE. Finally, a system cost analysis is presented for different length GHEs and a comparison of the total energy savings is obtained. The GSHP systems, although providing a sustainable and higher performance when compared to custom designed ASHPs, are proven to still fail to be a viable investment.
URI: https://hdl.handle.net/20.500.14279/15745
Type: Conference Papers
Affiliation: Cyprus University of Technology 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
ESCC2019 Abstract GF.pdf86.07 kBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

Page view(s) 50

329
Last Week
1
Last month
7
checked on 22 Δεκ 2024

Download(s)

87
checked on 22 Δεκ 2024

Google ScholarTM

Check


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα