Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/1504
Τίτλος: | Hemodynamic evaluation with turbo brisk - a rapid phase contrast angiography technique | Συγγραφείς: | Kortright, Eduardo Doyle, Mark W. Anayiotos, Andreas |
metadata.dc.contributor.other: | Αναγιωτός, Ανδρέας | Major Field of Science: | Engineering and Technology | Field Category: | ENGINEERING AND TECHNOLOGY | Λέξεις-κλειδιά: | Atherosclerosis;Hemodynamics;Blood--Rheology;Signal processing;Lactate dehydrogenase virus | Ημερομηνία Έκδοσης: | 1-Δεκ-2000 | Πηγή: | Technology and Health Care, 2000, vol. 8, no. 6, pp. 327-342 | Volume: | 8 | Issue: | 6 | Start page: | 327 | End page: | 342 | Περιοδικό: | Technology and Health Care | Περίληψη: | Hemodynamic imaging by phase contrast angiography was significantly accelerated by selective interpolation and segmentation in k-space using TURBO BRISK. The method was tested in vitro on three independent flow fields, representative of human blood rheology: a straight tube simulating the descending aorta, a curved tube simulating the aortic arch and a two-chamber orifice flow model simulating valvular regurgitation. The results were compared to data obtained by Laser Doppler Velocimetry (LDV) and showed good agreement. For the straight tube, the flow velocity obtained by five TURBO BRISK methods with increasing segmentation factors and corresponding time savings showed good agreement with LDV. For the curved tube, the velocity showed good general agreement with some differences in the decelerating part of the cycle, and in the low-velocity secondary flow structures. The orifice flow evaluation, the most time consuming case, was performed by the control volume method. It showed good agreement with actual flows through the orifice. Data acquisitions for TURBO-4 BRISK could be performed in 20s for each velocity component. The method shows promise for breath-hold acquisitions in clinical applications, including calculation of blood flow volumes through diseased arteries, measurement of blood backflow volumes through dysfunctional heart valves to time valve replacement operations, and evaluation of arterial wall shear stress, an important factor in the genesis of atherosclerosis. | URI: | https://hdl.handle.net/20.500.14279/1504 | ISSN: | 09287329 | DOI: | 10.3233/THC-2000-8602 | Rights: | © IOS Press | Type: | Article | Affiliation: | University of Alabama at Birmingham | Affiliation: | University of New Orleans University of Alabama at Birmingham |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
4
checked on 21 Μαρ 2021
Page view(s)
442
Last Week
1
1
Last month
3
3
checked on 23 Νοε 2024
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons