Τίτλος: | First in situ determination of the thermal performance of a U-pipe borehole heat exchanger, in Cyprus | Συγγραφείς: | Florides, Georgios A. Kalogirou, Soteris A. |
Major Field of Science: | Engineering and Technology | Field Category: | Environmental Engineering | Λέξεις-κλειδιά: | Borehole;Ground thermal conductivity;Line source method | Ημερομηνία Έκδοσης: | Φεβ-2008 | Πηγή: | Applied Thermal Engineering, 2008, vol. 28, no. 2-3, pp. 157-163 | Volume: | 28 | Issue: | 2-3 | Start page: | 157 | End page: | 163 | Περιοδικό: | Applied Thermal Engineering | Περίληψη: | A ground heat exchanger can be used for the injection or extraction of thermal energy into/from the ground. The line source model is an easy method of evaluating the characteristics of the borehole and does not need expensive equipment. This method is presented and a test is performed in order to determine a borehole’s characteristics in layers consisting of clay, silt and sand at various analogies. For the borehole under test the ground thermal conductivity (λ) was found to be 1.605 W/(m K) and the effective borehole thermal resistance (Rb) to be 0.257 K/(W/m). The accuracy of the collected data could be affected mainly by two factors. The first factor is the daily flux penetration through the ground which gradually increases the temperature of the top layers and the second factor is a variation of the heating coil injection rate per active length of borehole. As it was observed this combined effect has a negligible result on the mean fluid temperature during the test hours of 280–400, when the system was operating at steady state. The steady state conditions yield values of borehole thermal resistance which deviates about 25% from the values given by the line source method. The ground thermal conductivity deviates only about 5%. This method however is not suitable for estimating the above values because of the uncertainty that exists in the estimation of the mean ground temperature, which is not constant throughout the borehole length nor is it constant at different points in a cross section of the grout. Also this method takes a lot of time until the steady state is reached. | URI: | https://hdl.handle.net/20.500.14279/1430 | ISSN: | 13594311 | DOI: | 10.1016/j.applthermaleng.2007.03.026 | Rights: | © Elsevier 2007 | Type: | Article | Affiliation: | Higher Technical Institute Cyprus | Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
82
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
72
Last Week
0
0
Last month
0
0
checked on 28 Οκτ 2023
Page view(s)
490
Last Week
0
0
Last month
2
2
checked on 27 Νοε 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα