Τίτλος: | Design Procedure and Simplified Equations for the Flexural Capacity of Concrete Members Reinforced with Fibre-reinforced Polymer Bars | Συγγραφείς: | Torres, Lluís Neocleous, Kyriacos Pilakoutas, Kypros |
metadata.dc.contributor.other: | Νεοκλέους, Κυριάκος Πιλακούτας, Κύπρος |
Major Field of Science: | Engineering and Technology | Field Category: | Civil Engineering | Λέξεις-κλειδιά: | Concrete crushing;Design;Flexural capacity;FRP bars;FRP rupture;Reinforced concrete | Ημερομηνία Έκδοσης: | 4-Ιου-2012 | Πηγή: | Structural Concrete,2012, vol. 13, no. 2, pp.119-129 | Volume: | 13 | Issue: | 2 | Start page: | 119 | End page: | 129 | Περιοδικό: | Structural Concrete | Περίληψη: | The predominant failure mode of concrete members reinforced with fibre-reinforced polymer (FRP) bars is flexural, due to either concrete crushing or FRP rupture. Many design tools have been developed for the flexural design of FRP-reinforced concrete. These tools are sufficiently accurate, but an iterative procedure is required when dealing with flexural failure due to FRP rupture. In addition, despite the fact that the design concepts involved are similar to those used for conventional steel-reinforced concrete, the changes in the design philosophy and the linear behaviour up to rupture of the FRP bars lead to the sectional properties having a different influence on the design, which not everyone may be familiar with. Therefore, this study proposes a general methodology for evaluating the design flexural capacity of FRP-reinforced concrete sections. This methodology is based on the design provisions of Eurocode 2 and comprises non-dimensional, closed-form equations, derived independently of the concrete and FRP characteristics. The proposed methodology can be used to derive universal dimensionless design charts as well as tables. The accuracy of the proposed design tools has been verified by comparing the predictions with the experimental results of 98 beams, which are available in the published literature. Copyright © 2012 Ernst & Sohn Verlag für Architektur und technische Wissenschaften GmbH & Co. KG, Berlin. | ISSN: | 17517648 | DOI: | 10.1002/suco.201100045 | Rights: | © 2012 Ernst & Sohn | Type: | Article | Affiliation: | University of Girona University of Sheffield |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
18
checked on 6 Νοε 2023
WEB OF SCIENCETM
Citations
14
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s)
303
Last Week
0
0
Last month
4
4
checked on 30 Ιαν 2025
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα