Repository logoCyprus University of Technology
Log In(current)
Ελληνικά
English
  1. Home
  2. Cyprus University of Technology (Research Output)
  3. Άρθρα/Articles
  4. Shear stress at a compliant model of the human carotid bifurcation
  • Details

Shear stress at a compliant model of the human carotid bifurcation

Journal
Journal of biomechanical engineering
Date Issued
February 1994
Author(s)
Jones, Steve A.  
Giddens, Don P.  
Anayiotos, Andreas  
DOI
10.1115/1.2895710
Abstract
To investigate the role of a compliant wall to the near wall hemodynamic flowfield, two models of the carotid bifurcation were constructed. Both were of identical internal geometries, however, one was made of compliant material which produced approximately the same degree of wall motion as that occurring in vivo while the other one was rigid. The inner geometries were formed from the same mold so that the configurations are directly comparable. Each model was placed in a pulsatile flow system that produced a physiologic flow waveform. Velocity was measured with a single component Laser system and wall shear rate was estimated from near wall data. Wall motion in the compliant model was measured by a wall motion transducer and the maximum diameter change varied between 4-7 percent in the model with the greatest change at the axis intersection. The mean shear stress in the compliant model was observed to be smaller by about 30 percent at most locations. The variation in peak shear stress was greater and occasionally reached as much as 100 percent with the compliant model consistently having smaller positive and negative peaks. The separation point was seen to move further upstream in the compliant cast. The modified flowfield in the presence of a compliant wall can then be important in the hemodynamic theory of atherogenesis.
To investigate the role of a compliant wall to the near wall hemodynamic flowfield, two models of the carotid bifurcation were constructed. Both were of identical internal geometries, however, one was made of compliant materials which produced approximately the same degree of wall motion as that occurring in vivo while the other one was rigid. The inner geometries were formed from the same mold so that the configurations are directly comparable. Each model was placed in a pulsatile flow system that produced a physiologic flow waveform. Velocity was measured with a single component Laser system and wall shear rate was estimated from near wall data. Wall motion in the compliant model was measured by a wall motion transducer and the maximum diameter change varied between 4-7 percent in the model with the greatest change at the axis intersection. The mean shear stress in the compliant model was observed to be smaller by about 30 percent at most locations. The variation in peak shear stress was greater and occasionally reached as much as 100 percent with the compliant model consistently having smaller positive and negative peaks. The separation point was seen to move further upstream in the compliant cast. The modified flow field in the presence of a compliant wall can the be important in the hemodynamic theory of atherogenesis.
Subjects

Cardiovascular system...

Transducers

Hemodynamics

Blood

Explore by
  • Collections
  • Research Outputs
  • Researchers
  • Faculty & Departments
  • Theses
  • Patents
  • Projects
  • Journals
  • Conferences
Useful Links
  • Researcher Portfolio Guide
  • Researcher Profile
  • Create an ORCID ID
  • CUT Open Access Author Fund
  • ETDS Guide
Copyright Policies

Use Sherpa/Romeo to find publisher copyright policies

Go
Go
  • SPARC Author Addendum Engine
  • National Open Access Policy in Cyprus
Deposit your work to Ktisis
  • Self-archiving. Please sign in to Ktisis.
  • Email your work to:
    library.dspace@cut.ac.cy
  • Contact your subject librarian

Member of

OpenAIREre3dataOpenDOARCOREDART
Cyprus University of Technology
Library and
Information
Services

Copyright © 2022 - Library and Information Services Feedback - Built with DSpace-CRIS - 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
COAR NotifyCOAR Notify