Τίτλος: Noninvasive temperature estimation in tissue via ultrasound echo- shifts. Part I. Analytical model
Συγγραφείς: Maass-Moreno, Roberto 
Damianou, Christakis A. 
Major Field of Science: Engineering and Technology
Field Category: ENGINEERING AND TECHNOLOGY;Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Acoustics;Body Temperature;Humans;Models, Biological;Ultrasonics
Ημερομηνία Έκδοσης: 1-Οκτ-1996
Πηγή: Journal of the Acoustical Society of America, 1996, vol. 100, no. 4, pp. 2514-2521
Volume: 100
Issue: 4
Start page: 2514
End page: 2521
Περιοδικό: Journal of the Acoustical Society of America 
Περίληψη: Temperature changes in tissue, caused by high-intensity focused ultrasound, cause time shifts in the echoes that traverse the heated tissue. These time shifts are caused by thermally induced changes in the distribution of the velocity of sound and by thermal expansion within the tissue. Our analytical model relates these shifts to changes in temperature distribution. It is proposed that these relationships can be used as a method for the noninvasive estimation of temperature within the tissue. The model shows that the echo shifts depend mostly on changes in the mean velocity along the acoustical path of the echoes and that no explicit information about the shape of the velocity distribution is required. The effects of the tissue thermal expansion are small in comparison, but may be significant under certain conditions. The theory, as well as numerical simulations, also predicts that the time shifts have an approximately linear behavior as a function of temperature. This suggests that an empirical linear delay- temperature relationship can be determined for temperature prediction. It is also shown that, alternatively, the distribution of temperature in the tissue can be estimated from the distribution of echo delays along the acoustical path. In the proposed system, low-level pulse echoes are sampled during brief periods when the high-intensity ultrasonic irradiation is off, and thus linear acoustic behavior is assumed. The possibility of nonlinear aftereffects and other disturbances limiting this approach is discussed.
ISSN: 00014966
DOI: 10.1121/1.417359
Rights: © AIP Publishing LLC
Type: Article
Affiliation: Indianapolis Center for Advanced Research 
Indiana University 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

6
checked on 1 Φεβ 2024

WEB OF SCIENCETM
Citations

141
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

279
Last Week
5
Last month
5
checked on 22 Ιουν 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα