Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/13866
DC FieldValueLanguage
dc.contributor.authorSchenck, John F.-
dc.contributor.authorHynynen, Kullervo-
dc.contributor.authorUnger, Evan-
dc.contributor.authorDarkazanli, Ammar-
dc.contributor.authorDamianou, Christakis A.-
dc.date.accessioned2019-05-31T08:09:22Z-
dc.date.available2019-05-31T08:09:22Z-
dc.date.issued1994-01-01-
dc.identifier.citationInvestigative Radiology, 1994, vol. 29, no. 10, pp. 897-903en_US
dc.identifier.issn00209996-
dc.description.abstractRationale and Objectives. The ability of magnetic resonance imaging to detect small temperature elevations from focused ultrasound surgery beams was studied. In addition, the value of a contrast agent in delineating the necrosed tissue volume was investigated. materials and methods. Gradient-recalled acquisition in a steady state (GRASS) T1-weighted images were used to follow the temperature elevation and tissue changes during 2-minute sonications in the thigh muscles of 10 rabbits. The effects of the treatment on the vascular network was investigated by injecting a contrast agent bolus before or after the son-ication. Results. The signal intensity decreased during the sonica-tion, and the reduction was directly proportional to the applied power and increase in temperature. The signal intensity returned gradually back to baseline after the ultrasound was turned off. Injection of the contrast agent increased the signal intensity in muscle, but not in the necrosed tissue. The dimensions of the delineated tissue volume were the same as mca-sured from the T2-weightcd fast-spin-echo images and postmortem tissue examination. Conclusions. These results indicate that magnetic resonance imaging can be used to detect temperature elevations that do not cause tissue damage and that contrast agent can be used to delineate the necrosed tissue volume. © 1994. J.B. Lippincott Company.en_US
dc.language.isoenen_US
dc.relation.ispartofInvestigative Radiologyen_US
dc.rights© Wolters Kluweren_US
dc.subjectContrast agenten_US
dc.subjectMagnetic resonance imagingen_US
dc.subjectSurgeryen_US
dc.subjectUltrasounden_US
dc.titleThe usefulness of a contrast agent and gradient-recalled acquisition in a steady-state imaging sequence for magnetic resonance imaging-guided noninvasive ultrasound surgeryen_US
dc.typeArticleen_US
dc.collaborationUniversity of Arizonaen_US
dc.collaborationGeneral Electric Companyen_US
dc.collaborationHarvard Universityen_US
dc.subject.categoryElectrical Engineering - Electronic Engineering - Information Engineeringen_US
dc.journalsSubscriptionen_US
dc.countryUnited Statesen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.identifier.doi10.1097/00004424-199410000-00006en_US
dc.identifier.pmid29en
dc.identifier.scopus2-s2.0-0028619015en
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/0028619015en
dc.contributor.orcid#NODATA#en
dc.contributor.orcid#NODATA#en
dc.contributor.orcid#NODATA#en
dc.contributor.orcid#NODATA#en
dc.contributor.orcid#NODATA#en
dc.relation.issue10en_US
dc.relation.volume29en_US
cut.common.academicyear1995-1996en_US
dc.identifier.spage897en_US
dc.identifier.epage903en_US
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.openairetypearticle-
item.languageiso639-1en-
crisitem.journal.journalissn1536-0210-
crisitem.journal.publisherWolters Kluwer-
crisitem.author.deptDepartment of Electrical Engineering, Computer Engineering and Informatics-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-0424-2851-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

SCOPUSTM   
Citations

8
checked on Feb 1, 2024

WEB OF SCIENCETM
Citations

60
Last Week
0
Last month
0
checked on Oct 29, 2023

Page view(s) 50

287
Last Week
1
Last month
11
checked on May 11, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.