Τίτλος: MR monitoring of focused ultrasonic surgery of renal cortex: Experimental and simulation studies
Συγγραφείς: Unger, Evan 
Colucci, Vincent 
Hynynen, Kullervo 
Damianou, Christakis A. 
Cline, Harvey H. 
Jolesz, Ferenc A. 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Hyperthermla;Kidney;MR;Kidney, surgery;Magnetic resonance (MR) guidance;Temperature monitoring;Ultrasound;Therapeutic
Ημερομηνία Έκδοσης: 1-Μαΐ-1995
Πηγή: Journal of Magnetic Resonance Imaging, 1995, vol. 5, no. 3, pp. 259-266
Volume: 5
Issue: 3
Start page: 259
End page: 266
Περιοδικό: Journal of Magnetic Resonance Imaging 
Περίληψη: The aim of the study was to test the hypothesis that magnetic resonance (MR) imaging‐guided and ‐monitored noninvasive ultrasonic surgery can be performed in highly perfused tissues from outside the body. A simulation study was performed to evaluate the optimal sonication parameters. An MR‐compatible positioning device was then used to manipulate a focused ultrasound transducer in an MR imager, which was used to sonicate kidneys of five rabbits at various power levels and different durations. Temperature elevation during sonication was monitored with a T1‐ weighted spoiled gradient‐echo sequence. The simulation study demonstrated that a sharply focused transducer and relatively short sonication times (30 seconds or less) are necessary to prevent damage to the overlying skin and muscle tissue, which have a much lower blood perfusion rate than kidney. The experiments showed that the imaging sequence was sensitive enough to show temperature elevation during sonication, thereby Indicating the location of the beam focus. Histologic evaluations showed that kidney necrosis could be consistently induced without damage to overlying skin and muscle. The study demonstrated that highly perfused tissues such as the renal cortex can be coagulated from outside the body with focused ultrasound and that MR imaging can be used to guide and monitor this surgery. Copyright © 1995 Wiley‐Liss, Inc., A Wiley Company
ISSN: 15222586
DOI: 10.1002/jmri.1880050306
Rights: © Wiley
Type: Article
Affiliation: Harvard University 
University of Arizona Health Sciences Center 
General Electric Company 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

30
checked on 1 Φεβ 2024

WEB OF SCIENCETM
Citations

56
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

252
Last Week
2
Last month
10
checked on 14 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα