Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/13539
Τίτλος: | A New Method for Diaphragmatic Maximum Relaxation Rate Ultrasonographic Measurement in the Assessment of Patients With Diaphragmatic Dysfunction | Συγγραφείς: | Loizou, Christos P. Matamis, Dimitrios Minas, Giorgos Kyprianou, Theodoros Loizou, Christakis D. Soilemezi, Eleni Kotco, Entela Pattichis, Constantinos S. |
Major Field of Science: | Natural Sciences;Engineering and Technology | Field Category: | Computer and Information Sciences;Electrical Engineering - Electronic Engineering - Information Engineering | Λέξεις-κλειδιά: | Diaphragmatic muscle;Diaphragmatic motion analysis;Diaphragmatic ultrasound;Maximum relaxation rate (MRR) | Ημερομηνία Έκδοσης: | 11-Οκτ-2018 | Πηγή: | IEEE Journal of Translational Engineering in Health and Medicine, 2018, vol. 6 | Volume: | 6 | Περιοδικό: | IEEE Journal of Translational Engineering in Health and Medicine | Περίληψη: | Measurements of ultrasound diaphragmatic motion, amplitude, force, and velocity of contraction may provide important and essential information about diaphragmatic fatigue, weakness, or paralysis. In this paper, we propose and evaluate a semi-automated analysis system for measuring the diaphragmatic motion and estimating the maximum relaxation rate (MRR_SAUS) from ultrasound M-mode images of the diaphragmatic muscle. The system was evaluated on 27 M-mode ultrasound images of the diaphragmatic muscle [20 with no resistance (NRES) and 7 with resistance (RES)]. We computed semi-automated ultrasound MRR measurements on all NRES/RES images, using the proposed system (MRR_SAUS = 3.94 ± 0.91/4.98 ± 1.98 [1/s]), and compared them with the manual measurements made by a clinical expert (MRR_MUS = 2.36 ± 1.19/5.8 ± 2.1 [1/s],) and those made by a reference manual method (MRR_MB = 3.93 ± 0.89/3.73 ± 0.52 [1/sec], performed manually with the Biopac system. MRR_SAUS and MRR_MB measurements were not statistically significantly different for NRES and RES subjects but were significantly different with the MRR-MUS measurements made by the clinical expert. It is anticipated that the proposed system might be used in the future in the clinical practice in the assessment and follow up of patients with diaphragmatic weakness or paralysis. It may thus potentially help to understand post-operative pulmonary dysfunction or weaning failure from mechanical ventilation. Further validation and additional experimentation in a larger sample of images and different patient groups is required for further validating the proposed system. | ISSN: | 21682372 | DOI: | 10.1109/JTEHM.2018.2868671 | Rights: | © IEEE | Type: | Article | Affiliation: | Cyprus University of Technology Papageorgiou General Hospital Nicosia General Hospital Imperial College London University of Cyprus |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
08489971.pdf | Fulltext | 4.2 MB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
2
checked on 6 Νοε 2023
WEB OF SCIENCETM
Citations
50
2
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s) 50
369
Last Week
0
0
Last month
4
4
checked on 22 Δεκ 2024
Download(s)
156
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα