Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/13539
Title: A New Method for Diaphragmatic Maximum Relaxation Rate Ultrasonographic Measurement in the Assessment of Patients With Diaphragmatic Dysfunction
Authors: Loizou,  Christos P. 
Matamis, Dimitrios 
Minas, Giorgos 
Kyprianou, Theodoros 
Loizou, Christakis D. 
Soilemezi, Eleni 
Kotco, Entela 
Pattichis, Constantinos S. 
Major Field of Science: Natural Sciences;Engineering and Technology
Field Category: Computer and Information Sciences;Electrical Engineering - Electronic Engineering - Information Engineering
Keywords: Diaphragmatic muscle;Diaphragmatic motion analysis;Diaphragmatic ultrasound;Maximum relaxation rate (MRR)
Issue Date: 11-Oct-2018
Source: IEEE Journal of Translational Engineering in Health and Medicine, 2018, vol. 6
Volume: 6
Journal: IEEE Journal of Translational Engineering in Health and Medicine 
Abstract: Measurements of ultrasound diaphragmatic motion, amplitude, force, and velocity of contraction may provide important and essential information about diaphragmatic fatigue, weakness, or paralysis. In this paper, we propose and evaluate a semi-automated analysis system for measuring the diaphragmatic motion and estimating the maximum relaxation rate (MRR_SAUS) from ultrasound M-mode images of the diaphragmatic muscle. The system was evaluated on 27 M-mode ultrasound images of the diaphragmatic muscle [20 with no resistance (NRES) and 7 with resistance (RES)]. We computed semi-automated ultrasound MRR measurements on all NRES/RES images, using the proposed system (MRR_SAUS = 3.94 ± 0.91/4.98 ± 1.98 [1/s]), and compared them with the manual measurements made by a clinical expert (MRR_MUS = 2.36 ± 1.19/5.8 ± 2.1 [1/s],) and those made by a reference manual method (MRR_MB = 3.93 ± 0.89/3.73 ± 0.52 [1/sec], performed manually with the Biopac system. MRR_SAUS and MRR_MB measurements were not statistically significantly different for NRES and RES subjects but were significantly different with the MRR-MUS measurements made by the clinical expert. It is anticipated that the proposed system might be used in the future in the clinical practice in the assessment and follow up of patients with diaphragmatic weakness or paralysis. It may thus potentially help to understand post-operative pulmonary dysfunction or weaning failure from mechanical ventilation. Further validation and additional experimentation in a larger sample of images and different patient groups is required for further validating the proposed system.
ISSN: 21682372
DOI: 10.1109/JTEHM.2018.2868671
Rights: © IEEE
Type: Article
Affiliation : Cyprus University of Technology 
Papageorgiou General Hospital 
Nicosia General Hospital 
Imperial College London 
University of Cyprus 
Appears in Collections:Άρθρα/Articles

Files in This Item:
File Description SizeFormat
08489971.pdfFulltext4.2 MBAdobe PDFView/Open
CORE Recommender
Show full item record

SCOPUSTM   
Citations

2
checked on Nov 6, 2023

WEB OF SCIENCETM
Citations 50

2
Last Week
0
Last month
0
checked on Oct 29, 2023

Page view(s)

326
Last Week
2
Last month
23
checked on Apr 28, 2024

Download(s)

126
checked on Apr 28, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.