Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/13433
Τίτλος: | Nanotribological response of a-C:H coated metallic biomaterials: the cases of stainless steel, titanium, and niobium | Συγγραφείς: | Kapnisis, Konstantinos Constantinou, Marios Kyrkou, Maria Nikolaou, Petros Anayiotos, Andreas Constantinides, Georgios |
Major Field of Science: | Engineering and Technology | Field Category: | Materials Engineering | Λέξεις-κλειδιά: | Biomaterials;Hydrogenated amorphous carbon film;Nanoscratch;Nanotribology | Ημερομηνία Έκδοσης: | 1-Οκτ-2018 | Πηγή: | Journal of Applied Biomaterials and Functional Materials, 2018, vol. 16, no. 4, pp. 230-240 | Volume: | 16 | Issue: | 4 | Start page: | 230 | End page: | 240 | Περιοδικό: | Journal of Applied Biomaterials and Functional Materials | Περίληψη: | Background Wear and corrosion have been identified as two of the major forms of medical implant failures. This study aims to improve the surface, protective and tribological characteristics of bare metals used for medical implants, so as to improve scratch resistance and increase lifetime. Methods Hydrogenated amorphous carbon (a-C:H) films were deposited, using plasma enhanced chemical vapor deposition (PECVD), on stainless steel (SS), titanium (Ti) and niobium (Nb) metal plates. Nanomechanical and nanotribological responses were investigated before and after a-C:H deposition. Film thickness and density were quantified through X-ray reflectivity, and surface morphology before and after deposition were measured using atomic force microscopy, whereas the tribomechanical characteristics were probed using instrumented indentation. Results and conclusions Films of approximately 40 nm in thickness and density of 1.7 g/cm3 were deposited. The a-C:H films reduce the roughness and coefficient of friction while improving the tribomechanical response compared with bare metals for Ti, SS and Nb plates. The very good tribomechanical properties of a-C:H make it a promising candidate material for protective coating on metallic implants. | ISSN: | 22808000 | DOI: | 10.1177/2280800018782840 | Rights: | © The Author(s) | Type: | Article | Affiliation: | Cyprus University of Technology | Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
Nanotribological response of.pdf | Open Access | 851.03 kB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
50
2
checked on 6 Νοε 2023
WEB OF SCIENCETM
Citations
50
2
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s)
405
Last Week
1
1
Last month
4
4
checked on 3 Ιαν 2025
Download(s)
58
checked on 3 Ιαν 2025
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα