Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/13433
Τίτλος: Nanotribological response of a-C:H coated metallic biomaterials: the cases of stainless steel, titanium, and niobium
Συγγραφείς: Kapnisis, Konstantinos 
Constantinou, Marios 
Kyrkou, Maria 
Nikolaou, Petros 
Anayiotos, Andreas 
Constantinides, Georgios 
Major Field of Science: Engineering and Technology
Field Category: Materials Engineering
Λέξεις-κλειδιά: Biomaterials;Hydrogenated amorphous carbon film;Nanoscratch;Nanotribology
Ημερομηνία Έκδοσης: 1-Οκτ-2018
Πηγή: Journal of Applied Biomaterials and Functional Materials, 2018, vol. 16, no. 4, pp. 230-240
Volume: 16
Issue: 4
Start page: 230
End page: 240
Περιοδικό: Journal of Applied Biomaterials and Functional Materials 
Περίληψη: Background Wear and corrosion have been identified as two of the major forms of medical implant failures. This study aims to improve the surface, protective and tribological characteristics of bare metals used for medical implants, so as to improve scratch resistance and increase lifetime. Methods Hydrogenated amorphous carbon (a-C:H) films were deposited, using plasma enhanced chemical vapor deposition (PECVD), on stainless steel (SS), titanium (Ti) and niobium (Nb) metal plates. Nanomechanical and nanotribological responses were investigated before and after a-C:H deposition. Film thickness and density were quantified through X-ray reflectivity, and surface morphology before and after deposition were measured using atomic force microscopy, whereas the tribomechanical characteristics were probed using instrumented indentation. Results and conclusions Films of approximately 40 nm in thickness and density of 1.7 g/cm3 were deposited. The a-C:H films reduce the roughness and coefficient of friction while improving the tribomechanical response compared with bare metals for Ti, SS and Nb plates. The very good tribomechanical properties of a-C:H make it a promising candidate material for protective coating on metallic implants.
ISSN: 22808000
DOI: 10.1177/2280800018782840
Rights: © The Author(s)
Type: Article
Affiliation: Cyprus University of Technology 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
Nanotribological response of.pdfOpen Access851.03 kBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations 50

2
checked on 6 Νοε 2023

WEB OF SCIENCETM
Citations 50

2
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

405
Last Week
1
Last month
4
checked on 3 Ιαν 2025

Download(s)

58
checked on 3 Ιαν 2025

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα