Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/1135
Τίτλος: Lung sounds in neonates with and without an added dead space
Συγγραφείς: Blowes, R. W. 
Milner, Anthony David 
Yiallouros, Panayiotis K. 
metadata.dc.contributor.other: Γιάλλουρος, Παναγιώτης
Major Field of Science: Medical and Health Sciences
Field Category: Clinical Medicine
Λέξεις-κλειδιά: Lung sounds;Neonates;Auscultation
Ημερομηνία Έκδοσης: Ιου-1995
Πηγή: Pediatric Pulmonology, 1995, vol. 19, no. 6, pp. 348-354
Volume: 19
Issue: 6
Start page: 348
End page: 354
Περιοδικό: Pediatric Pulmonology 
Περίληψη: Previous studies have reported great difficulty in recording lung sounds from neonates and have found conflicting results. We studied lung sounds in neonates during the inspiratory phase of the respiratory cycle as monitored by inductive plethysmography (A) and by pneumotachograph and face mask (8) which added dead space of 12 mL. Sixteen term babies were tested 12 hr to 6 days (median 45 hours) after birth. Lung sounds were recorded and then analysed using overlapping and nonoverlapping fast Fourier transforms. The two methods of analysis showed difference in intensity but not in frequency. Fourteen babies provided enough breaths for comparison; total of 596 inspirations were analysed. The intensity of lung sounds on occasion B was higher in all but two babies with mean B/A ratio of 2.4. The mean (SD) power on occasions A and B was 13.9(8.5) mW and 26.9 (21.0) mW, P = 0.02, respectively. In all but 4 babies the B/A ratios of the median (f50) and 90th centile (f90) frequencies were scattered randomly within 20% of unity. The mean (SD) f50 on occasions A and B was 205.5 (51.1) Hz and 225.8 (32.3) Hz, P = 0.10, respectively; the mean f50 was 370.3 (91.0) Hz and 396.1 (67.8) Hz, P = 0.25, respectively. Linear regression showed that there is third-order polynomial relationship between sound intensity and air flow at the mouth. A weaker positive association exists between frequency and air flow, showing that the median and 90th centile frequencies approach an asymptote as flow increases. We conclude that adding dead space increases the intensity of lung sounds in neonates due to increased flow, but has no consistent effect on frequency content.
URI: https://hdl.handle.net/20.500.14279/1135
ISSN: 10990496
DOI: 10.1002/ppul.1950190607
Rights: © Wiley
Type: Article
Affiliation: St. Thomas' Hospital 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

4
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations 50

4
Last Week
0
Last month
0
checked on 25 Οκτ 2023

Page view(s) 20

475
Last Week
4
Last month
15
checked on 11 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα