Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/11025
Τίτλος: | A cognitive monitoring system for detecting and isolating contaminants and faults in intelligent buildings | Συγγραφείς: | Boracchi, Giacomo Mo Michaelides, Michalis P. Roveri, Manuel |
Major Field of Science: | Engineering and Technology | Field Category: | Electrical Engineering - Electronic Engineering - Information Engineering | Λέξεις-κλειδιά: | Change detection tests;Change point methods;Chemical and biological sensors;Cognitive monitoring system;Contaminants detection;Fault detection;Gas detectors;Hierarchical system;Indoor air quality;Intelligent buildings;Isolation and identification algorithms;Sensor faults | Ημερομηνία Έκδοσης: | Μαρ-2018 | Πηγή: | IEEE Transactions on Systems, Man, and Cybernetics: Systems, 2018, vol. 48, no. 3, pp. 433 - 447 | Volume: | 48 | Issue: | 3 | Start page: | 433 | End page: | 447 | Περιοδικό: | IEEE Transactions on Systems, Man, and Cybernetics: Systems | Περίληψη: | Intelligent buildings are typically endowed with sensing devices that are able to measure the concentration of specific contaminants in relevant zones. The collected measurements are subsequently processed by intelligent algorithms in order to enable the prompt detection and isolation of contaminant sources inside the building. Unfortunately, in real-world conditions, these sensing devices may suffer from faults affecting the sensors or the embedded electronics. Such faults, generally result in perturbed or missed data in the acquired data-stream, that can induce false alarms (or possibly missed alarms) and compromise the contaminant detection and isolation ability. This paper proposes a three-layer cognitive monitoring system for the detection and isolation of both contaminants and sensor faults in intelligent buildings. The first two layers are designed for the prompt detection of small variations in the concentration of a specific contaminant, while reducing the possible occurrence of false alarms. At the third layer, a cognitive mechanism employing a propagation model for the contaminant, which is based on the airflows between the building zones, allows to isolate the source zone and discriminate between sensor faults and the presence of a contaminant source. The proposed method is validated using a realistic 14-zone building scenario. | URI: | https://hdl.handle.net/20.500.14279/11025 | ISSN: | 21682216 | DOI: | 10.1109/TSMC.2016.2608419 | Rights: | © IEEE | Type: | Article | Affiliation: | Politecnico di Milano Cyprus University of Technology |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
9
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
20
8
Last Week
0
0
Last month
0
0
checked on 31 Οκτ 2023
Page view(s) 20
479
Last Week
0
0
Last month
4
4
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα