Τίτλος: | Acoustic and thermal characterization of agar based phantoms used for evaluating focused ultrasound exposures | Συγγραφείς: | Menikou, Georgios Damianou, Christakis A. |
Major Field of Science: | Medical and Health Sciences | Field Category: | Electrical Engineering - Electronic Engineering - Information Engineering;Other Medical Sciences | Λέξεις-κλειδιά: | Ultrasound;Agar;Attenuation;Conductivity | Ημερομηνία Έκδοσης: | 1-Ιου-2017 | Πηγή: | Journal of Therapeutic Ultrasound, 2017, vol. 5, no. 1 | Volume: | 5 | Issue: | 1 | Περιοδικό: | Journal of Therapeutic Ultrasound | Περίληψη: | Background This study describes a series of experimental work completed towards characterizing candidate materials for fabricating brain and muscle tissue mimicking phantoms. Methods The acoustic speed, attenuation, impedance, thermal diffusivity, specific heat and thermal conductivity were measured. Results The resulting brain (2% w/v agar-1.2% w/v Silica Dioxide-25%v/v evaporated milk) and muscle tissue recipe (2% w/v agar-2% w/v Silica Dioxide-40%v/v evaporated milk) introduced a total attenuation coefficient of 0.59 dB/cm-MHz and 0.99 dB/cm-MHz respectively. Acrylonitrile Butadiene Styrene (ABS) possessed an attenuation coefficient of 16 dB/cm at 1 MHz which was found within the very wide range of attenuation coefficient values of human bones in literature. The thermal conductivity of the brain tissue phantom was estimated at 0.52 W/m°C and at 0.57 W/m.°Cfor the muscle. These values demonstrated that the proposed recipes conducted heat similar to the majority of most soft tissues found from bibliography. The soft tissue phantoms were also evaluated for their thermal repeatability after treating them repeatedly at different locations with the same sonication protocol and configuration. The average coefficient of variation of the maximum temperature at focus between the different locations was 2.6% for the brain phantom and 2.8% for the muscle phantom. Conclusions The proposed phantom closely matched the acoustic and thermal properties of tissues. Experiments using MR thermometry demonstrated the usefulness of this phantom to evaluate ultrasonic exposures. | URI: | https://hdl.handle.net/20.500.14279/10543 | ISSN: | 20505736 | DOI: | 10.1186/s40349-017-0093-z | Rights: | © The Author(s). This article is distributed under the terms of the Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver applies to the data made available in this article, unless otherwise stated. | Type: | Article | Affiliation: | Cyprus University of Technology University of London |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
document.pdf | 2.77 MB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
53
checked on 9 Νοε 2023
Page view(s)
487
Last Week
0
0
Last month
4
4
checked on 6 Νοε 2024
Download(s)
140
checked on 6 Νοε 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα