Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/10502
Τίτλος: Heat transfer and sensitivity analysis in a double pipe heat exchanger filled with porous medium
Συγγραφείς: Milani Shirvan, Kamel 
Mirzakhanlari, Soroush 
Kalogirou, Soteris A. 
Öztop, Hakan F. 
Mamourian, Mojtaba 
Major Field of Science: Engineering and Technology
Field Category: Other Engineering and Technologies
Λέξεις-κλειδιά: Response surface methodology;Sensitivity analysis;Heat exchanger effectiveness double pipe;Heat exchanger;Heat transfer;Porous medium
Ημερομηνία Έκδοσης: Νοε-2017
Πηγή: International Journal of Thermal Sciences, 2017, vol. 121, pp. 124-137
Volume: 121
Start page: 124
End page: 137
Περιοδικό: International Journal of Thermal Sciences 
Περίληψη: In this paper, 2-D numerical investigation and sensitivity analysis are performed on heat transfer rate and heat exchanger effectiveness of a double pipe heat exchanger filled with porous medium. The Darcy -Brinkman-Forchheimer model is applied to model the flow field in the porous zone. The sensitivity analysis is performed utilizing the Response Surface Methodology. The studied parameters are: Reynolds number (50 <= Re <= 250), Darcy number (10(-5) <= Da <= 10(-3)), temperature difference between hot and cold fluids (30 <= Delta T <= 70) and the porous substrate thickness (1/3 <= delta <= 1). The obtained results showed that enhancement of the Nusselt number due to the increase in Reynolds and Darcy numbers is in the vicinity of the 77.84% for the case with delta = 2/3 and Da =10(-5) to 10(-3), and 203.25% for the case with delta =1 and Re = 50 to 250. Furthermore, increasing porous substrate thickness reduces the mean Nusselt number until delta = 2/3 and then increases it. In addition, it is found that the heat exchanger effectiveness increases with the Re number and reduces with enhancement of the Da number. The sensitivity analysis showed that the sensitivity of the mean Nusselt number to the Re and Da numbers and the porous substrate thickness is positive, while the sensitivity of the heat exchanger effectiveness to the Re number is positive but to the Da number is negative.
URI: https://hdl.handle.net/20.500.14279/10502
ISSN: 12900729
DOI: 10.1016/j.ijthermalsci.2017.07.008
Rights: © Elsevier
Type: Article
Affiliation: Cyprus University of Technology 
Ferdowsi University of Mashhad 
Islamic Azad University 
Firat University 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

46
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations 20

40
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

486
Last Week
0
Last month
1
checked on 6 Νοε 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα