Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/10108
Τίτλος: Methodology for estimating the ground heat absorption rate of Ground Heat Exchangers
Συγγραφείς: Stylianou, Iosifina Iosif 
Florides, Georgios A. 
Tassou, Savvas A. 
Tsiolakis, Efthymios 
Christodoulides, Paul 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Geothermal energy;GIS;Ground geothermal properties;Ground Heat Exchangers;Heat load;Low enthalpy systems
Ημερομηνία Έκδοσης: Μαΐ-2017
Πηγή: Energy, 2017, vol. 127, pp. 258-270
Volume: 127
Start page: 258
End page: 270
Περιοδικό: Energy 
Περίληψη: In Ground Source Heat Pump systems, the heat exchange rate is an important factor with regard to the initial cost of the system. When the Ground Heat Exchanger (GHE) is installed in a lithology with high thermal properties in the presence of groundwater, the heat exchange rates are larger than in the cases with poor thermal response of the ground and no groundwater. This research, hence, focuses on a methodology of measuring and analyzing the thermal properties of the lithologies encountered in an area, which can be used for the prediction of heat injection rates of a GHE, depending on its characteristics, the installation area ground properties and groundwater flow. A tool was created with the use of FlexPDE software, and a study case was chosen in order to validate the results. Twenty-two, 100 m in depth, boreholes located in Lefkosia (Cyprus) were tested through simulation for their geothermal performance over time. Subsequently the estimated heat load for the boreholes, after 24 h of operation in cooling mode, was used with the help of Geographic Information System software for the compilation of a heat load per meter depth map that can be transferred to the ground by a GHE. A review of similar studies and Geographical Information System applications referring to other countries is also presented and their results are compared to the results of this study. The step by step procedure presented in this paper can be used by engineers handling geothermal projects as a useful guide for sizing GHEs and calculating the heat injection rates of any area.
URI: https://hdl.handle.net/20.500.14279/10108
ISSN: 03605442
DOI: 10.1016/j.energy.2017.03.070
Rights: © Elsevier
Type: Article
Affiliation: Brunel University London 
Cyprus University of Technology 
Ministry of Agriculture, Rural Development and Environment, Cyprus 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

9
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations

9
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s) 20

485
Last Week
2
Last month
3
checked on 22 Δεκ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα