Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/9790
DC FieldValueLanguage
dc.contributor.authorLoizou,  Christos P.-
dc.contributor.authorKasparis, Takis-
dc.contributor.authorSpyrou, Christina-
dc.contributor.authorPantziaris, Marios-
dc.date.accessioned2017-02-17T12:46:37Z-
dc.date.available2017-02-17T12:46:37Z-
dc.date.issued2013-12-
dc.identifier.citation9th IFIP WG 12.5 International Conference on Artificial Intelligence Applications and Innovations, 2013, Paphos, Cyprusen_US
dc.identifier.isbn978-364241141-0-
dc.descriptionOriginally published with the title: IFIP International Federation for Information Processingen_US
dc.description.abstractThe complete segmentation of the common carotid artery (CCA) bifurcation in ultrasound images is important for the evaluation of atherosclerosis disease and the quantification of the risk of stroke. This requires the extraction of the intima-media complex (IMC), the delineation of the lumen the atherosclerotic carotid plaque and measurement of the artery stenosis. The current research proposes an automated segmentation system for the complete segmentation of the CCA bifurcation in ultrasound images, which is based on snakes. The algorithm was evaluated on 20 longitudinal ultrasound images of the CCA bifurcation with manual segmentations available from a neurovascular expert. The manual mean±SD measurements were for the IMT: (0.96±0.22) mm, lumen diameter: (5.59±0.84) mm and ICA origin stenosis (48.1±11.52) %, while the automated measurements were for the IMT: (0.93±0.22) mm, lumen diameter: (5.77±0.99) mm and ICA stenosis (51.05±14.51) % respectively. We found no significant differences between all manual and the automated segmentation measurements.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.rights© IFIP International Federation for Information Processing 2013.en_US
dc.subjectAtherosclerotic plaqueen_US
dc.subjectCarotid arteryen_US
dc.subjectCarotid segmentationen_US
dc.subjectUltrasound imageen_US
dc.subjectIntima-media thicknessen_US
dc.subjectLumen diameteren_US
dc.titleIntegrated system for the complete segmentation of the common carotid artery bifurcation in ultrasound imagesen_US
dc.typeConference Papersen_US
dc.collaborationCyprus University of Technologyen_US
dc.collaborationCyprus Institute of Neurology and Geneticsen_US
dc.subject.categoryElectrical Engineering - Electronic Engineering - Information Engineeringen_US
dc.subject.categoryMEDICAL AND HEALTH SCIENCESen_US
dc.subject.categoryClinical Medicineen_US
dc.countryCyprusen_US
dc.subject.fieldEngineering and Technologyen_US
dc.subject.fieldMedical and Health Sciencesen_US
dc.publicationPeer Revieweden_US
dc.relation.conferenceIFIP Advances in Information and Communication Technologyen_US
dc.identifier.doi10.1007/978-3-642-41142-7_30en_US
cut.common.academicyear2013-2014en_US
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_c94f-
item.openairetypeconferenceObject-
item.languageiso639-1en-
crisitem.author.deptDepartment of Electrical Engineering, Computer Engineering and Informatics-
crisitem.author.deptDepartment of Electrical Engineering, Computer Engineering and Informatics-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-1247-8573-
crisitem.author.orcid0000-0003-3486-538x-
crisitem.author.parentorgFaculty of Engineering and Technology-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation
CORE Recommender
Show simple item record

SCOPUSTM   
Citations

22
checked on Nov 6, 2023

Page view(s) 50

384
Last Week
2
Last month
11
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.