Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/9761
Title: | Use of satellite derived vegetation indices for the detection of water pipeline leakages in semiarid areas | Authors: | Agapiou, Athos Toulios, Leonidas G. Themistocleous, Kyriacos Perdikou, Skevi Alexakis, Dimitrios Sarris, Apostolos Toulios, Giorgos Clayton, Chris R I Phinikaridou, Helena Manoli, Andreas Hadjimitsis, Diofantos G. |
Major Field of Science: | Engineering and Technology | Field Category: | Electrical Engineering - Electronic Engineering - Information Engineering | Keywords: | Landsat ETM+;Low altitude system;Spectroradiometric measurements;Vegetation indices;Water leakages | Issue Date: | 1-Apr-2013 | Source: | 1st International Conference on Remote Sensing and Geoinformation of the Environment, RSCy 2013; Paphos; Cyprus; 8 April 2013 through 10 April 2013 | DOI: | 10.1117/12.2028241 | Abstract: | Remote sensing may be used for quick and cost effective detection and monitoring of water leakages, since traditional field survey methods for detection of water pipeline leakages are costly and time consuming. Vegetation indices are widely used by researchers for many applications. Among them, NDVI, RVI and SAVI are indices that can be used for pipeline leakage detection. In this study, the above vegetation indices were evaluated based on Landsat ETM+ multispectral images in a multi-temporal mode. The evaluation was performed in the semiarid environment in Cyprus, in order to detect the position of points/areas where water leakage occurs and to examine the accuracy of the vegetation indices in detecting such events. In addition, a low altitude system was used to record spectral differences before and after a leakage event. The results showed that there are leakage points that could be detected using satellite images due to the increasing and decreasing of the surrounding vegetation affected by the water leaked of the pipeline. Other characteristics such as the soil type and precipitation were also examined. Finally, the low altitude system highlighted the advantages of using such non contact techniques for monitoring water leakages. | URI: | https://hdl.handle.net/20.500.14279/9761 | ISBN: | 978-081949638-6 | Rights: | © 2013 SPIE. | Type: | Conference Papers | Affiliation : | Cyprus University of Technology Hellenic Agricultural Organization “Demeter” Frederick Research Center Foundation for Research & Technology-Hellas (F.O.R.T.H.) Southampton University Water Development Department |
Publication Type: | Peer Reviewed |
Appears in Collections: | Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation |
CORE Recommender
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.