dc.contributor.authorBerg, Philipp-
dc.contributor.authorRoloff, Christoph-
dc.contributor.authorBeuing, Oliver-
dc.contributor.authorVoss, Samuel-
dc.contributor.authorSugiyama, Shin-Ichiro-
dc.contributor.authorAristokleous, Nicolas-
dc.contributor.authorAnayiotos, Andreas-
dc.contributor.authorAshton, Neil-
dc.contributor.authorRevell, Alistair-
dc.contributor.authorBressloff, Neil W.-
dc.contributor.authorBrown, Alistair G.-
dc.contributor.authorChung, Bong Jae-
dc.contributor.authorCebral, Juan R.-
dc.contributor.authorCopelli, Gabriele-
dc.contributor.authorFu, Wenyu-
dc.contributor.authorQiao, Aike-
dc.contributor.authorGeers, Arjan J.-
dc.contributor.authorHodis, Simona-
dc.contributor.authorDragomir-Daescu, Dan-
dc.contributor.authorNordahl, Emily-
dc.contributor.authorSuzen, Yildirim Bora-
dc.contributor.authorKhan, Muhammad Owais-
dc.contributor.authorValen-Sendstad, Kristian-
dc.contributor.authorKono, Kenichi-
dc.contributor.authorMenon, Prahlad G.-
dc.contributor.authorAlbal, Priti G.-
dc.contributor.authorMierka, Otto-
dc.contributor.authorMünster, Raphael-
dc.contributor.authorMorales, Hernán G.-
dc.contributor.authorBonnefous, Odile-
dc.contributor.authorOsman, Jan-
dc.contributor.authorGoubergrits, Leonid-
dc.contributor.authorPallares, Jordi-
dc.contributor.authorCito, Salvatore-
dc.contributor.authorPassalacqua, Alberto-
dc.contributor.authorPiskin, Senol-
dc.contributor.authorPekkan, Kerem-
dc.contributor.authorRamalho, Susana-
dc.contributor.authorMarques, Nelson-
dc.contributor.authorSanchi, Stéphane-
dc.contributor.authorSchumacher, Kristopher R.-
dc.contributor.authorSturgeon, Jess-
dc.contributor.authorŠvihlová, Helena-
dc.contributor.authorHron, Jaroslav-
dc.contributor.authorUsera, Gabriel-
dc.contributor.authorMendina, Mariana-
dc.contributor.authorXiang, Jianping-
dc.contributor.authorMeng, Hui-
dc.contributor.authorSteinman, David A.-
dc.contributor.authorJaniga, Gábor-
dc.date.accessioned2017-01-23T10:23:33Z-
dc.date.available2017-01-23T10:23:33Z-
dc.date.issued2015-11-05-
dc.identifier.citationJournal of Biomechanical Engineering, 2015, vol. 137, no. 12.en_US
dc.identifier.issn01480731-
dc.identifier.urihttps://hdl.handle.net/20.500.14279/9183-
dc.description.abstractWith the increased availability of computational resources, the past decade has seen a rise in the use of computational fluid dynamics (CFD) for medical applications. There has been an increase in the application of CFD to attempt to predict the rupture of intracranial aneurysms, however, while many hemodynamic parameters can be obtained from these computations, to date, no consistent methodology for the prediction of the rupture has been identified. One particular challenge to CFD is that many factors contribute to its accuracy; the mesh resolution and spatial/temporal discretization can alone contribute to a variation in accuracy. This failure to identify the importance of these factors and identify a methodology for the prediction of ruptures has limited the acceptance of CFD among physicians for rupture prediction. The International CFD Rupture Challenge 2013 seeks to comment on the sensitivity of these various CFD assumptions to predict the rupture by undertaking a comparison of the rupture and blood-flow predictions from a wide range of independent participants utilizing a range of CFD approaches. Twenty-six groups from 15 countries took part in the challenge. Participants were provided with surface models of two intracranial aneurysms and asked to carry out the corresponding hemodynamics simulations, free to choose their own mesh, solver, and temporal discretization. They were requested to submit velocity and pressure predictions along the centerline and on specified planes. The first phase of the challenge, described in a separate paper, was aimed at predicting which of the two aneurysms had previously ruptured and where the rupture site was located. The second phase, described in this paper, aims to assess the variability of the solutions and the sensitivity to the modeling assumptions. Participants were free to choose boundary conditions in the first phase, whereas they were prescribed in the second phase but all other CFD modeling parameters were not prescribed. In order to compare the computational results of one representative group with experimental results, steady-flow measurements using particle image velocimetry (PIV) were carried out in a silicone model of one of the provided aneurysms. Approximately 80% of the participating groups generated similar results. Both velocity and pressure computations were in good agreement with each other for cycle-averaged and peaksystolic predictions. Most apparent "outliers" (results that stand out of the collective) were observed to have underestimated velocity levels compared to the majority of solutions, but nevertheless identified comparable flow structures. In only two cases, the results deviate by over 35% from the mean solution of all the participants. Results of steady CFD simulations of the representative group and PIV experiments were in good agreement. The study demonstrated that while a range of numerical schemes, mesh resolution, and solvers was used, similar flow predictions were observed in the majority of cases. To further validate the computational results, it is suggested that time-dependent measurements should be conducted in the future. However, it is recognized that this study does not include the biological aspects of the aneurysm, which needs to be considered to be able to more precisely identify the specific rupture risk of an intracranial aneurysm.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.relation.ispartofJournal of Biomechanical Engineeringen_US
dc.rights© ASME.en_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectChallengeen_US
dc.subjectComputational fluid dynamicsen_US
dc.subjectIntracranial aneurysmen_US
dc.subjectVariabilityen_US
dc.titleThe Computational Fluid Dynamics Rupture Challenge 2013 - Phase II: Variability of Hemodynamic Simulations in Two Intracranial Aneurysmsen_US
dc.typeArticleen_US
dc.doi10.1115/1.4031794en_US
dc.collaborationUniversity of Magdeburgen_US
dc.collaborationUniversity Hospital of Magdeburgen_US
dc.collaborationTohoku Universityen_US
dc.collaborationCyprus University of Technologyen_US
dc.collaborationUniversity of Manchesteren_US
dc.collaborationUniversity of Southamptonen_US
dc.collaborationCD-Adapcoen_US
dc.collaborationGeorge Mason Universityen_US
dc.collaborationUniversity of Parmaen_US
dc.collaborationBeijing University of Technologyen_US
dc.collaborationUniversitat Pompeu Fabraen_US
dc.collaborationTexas A and M Universityen_US
dc.collaborationMayo Clinicen_US
dc.collaborationNorth Dakota State Universityen_US
dc.collaborationUniversity of Torontoen_US
dc.collaborationWakayama Rosai Hospitalen_US
dc.collaborationCarnegie Mellon Universityen_US
dc.collaborationUniversity of Dortmunden_US
dc.collaborationMedisys—Philips Researchen_US
dc.collaborationCharité-Universitätsmedizin Berlinen_US
dc.collaborationUniversitat Rovira i Virgilien_US
dc.collaborationIowa State Universityen_US
dc.collaborationKoc Universityen_US
dc.collaborationBlueCAPE Lda—CAE Solutionsen_US
dc.collaborationPréverengesen_US
dc.collaborationMRIGlobalen_US
dc.collaborationCharles Universityen_US
dc.collaborationUniversidad de la Repúblicaen_US
dc.collaborationUniversity at Buffaloen_US
dc.subject.categoryPhysical Sciencesen_US
dc.journalsOpen Accessen_US
dc.countryGermanyen_US
dc.countryJapanen_US
dc.countryCyprusen_US
dc.countryUnited Kingdomen_US
dc.countryUnited Statesen_US
dc.countryItalyen_US
dc.countryChinaen_US
dc.countrySpainen_US
dc.countryCanadaen_US
dc.countryFranceen_US
dc.countryTurkeyen_US
dc.countryPortugalen_US
dc.countrySwitzerlanden_US
dc.countryCzech Republicen_US
dc.countryUruguayen_US
dc.subject.fieldNatural Sciencesen_US
dc.publicationPeer Revieweden_US
dc.identifier.doi10.1115/1.4031794en_US
dc.relation.issue12en_US
dc.relation.volume137en_US
cut.common.academicyear2015-2016en_US
item.languageiso639-1en-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairetypearticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0002-0206-7773-
crisitem.author.orcid0000-0003-4471-7604-
crisitem.author.parentorgFaculty of Engineering and Technology-
crisitem.author.parentorgFaculty of Engineering and Technology-
crisitem.journal.journalissn1528-8951-
crisitem.journal.publisherAmerican Society of Mechanical Engineers-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

SCOPUSTM   
Citations

72
checked on Nov 9, 2023

WEB OF SCIENCETM
Citations 10

63
Last Week
0
Last month
1
checked on Oct 29, 2023

Page view(s) 20

497
Last Week
0
Last month
3
checked on Oct 4, 2024

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons