Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/4353
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Fokaides, Paris A. | - |
dc.contributor.author | Maxoulis, Christos N. | - |
dc.contributor.author | Panayiotou, Gregoris | - |
dc.contributor.author | Neophytou, Marina K A | - |
dc.contributor.author | Kalogirou, Soteris A. | - |
dc.date.accessioned | 2013-03-04T10:49:05Z | en |
dc.date.accessioned | 2013-05-17T10:30:32Z | - |
dc.date.accessioned | 2015-12-09T12:07:57Z | - |
dc.date.available | 2013-03-04T10:49:05Z | en |
dc.date.available | 2013-05-17T10:30:32Z | - |
dc.date.available | 2015-12-09T12:07:57Z | - |
dc.date.issued | 2011-11 | - |
dc.identifier.citation | Energy and Buildings, 2011, vol. 43, no. 11, pp. 3099–3105 | en_US |
dc.identifier.issn | 03787788 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.14279/4353 | - |
dc.description.abstract | The objective of this study is to present a comparison between the measured and the calculated energy performance of dwellings. For this purpose, the energy consumption of ten dwellings is measured for one year. The added value of this work is that it is performed in a summer dominant environment. The energy needs of the same dwellings are also calculated by means of the methodology based on European Standards described in the CEN/TR 15615:2008 technical report. According to the findings of this study, a large gap exists between the calculated and the measured energy consumption of the examined dwellings. In order to evaluate the reasons for this deviation, a detailed analysis of the heating and cooling loads of the dwellings is performed. The intermittent heating of the building is found to be simulated accurately by the employed methodology, whereas the comparison between the calculated and the measured cooling loads reveals a large deviation of about 150%. Based on the findings of this study, a factor of 0.6 should be adopted in the case of cooling schedule, compared to the heating operation of the building | en_US |
dc.format | en_US | |
dc.language.iso | en | en_US |
dc.relation.ispartof | Energy and Buildings | en_US |
dc.rights | © Elsevier | en_US |
dc.subject | Buildings | en_US |
dc.subject | Air conditioning | en_US |
dc.subject | Apartment houses | en_US |
dc.subject | Cooling | en_US |
dc.title | Comparison between measured and calculated energy performance for dwellings in a summer dominant environment | en_US |
dc.type | Article | en_US |
dc.collaboration | University of Cyprus | en_US |
dc.collaboration | Cyprus Scientific and Technical Chamber | en_US |
dc.subject.category | Environmental Engineering | en_US |
dc.journals | Subscription | en_US |
dc.review | peer reviewed | - |
dc.country | Cyprus | en_US |
dc.subject.field | Engineering and Technology | en_US |
dc.publication | Peer Reviewed | en_US |
dc.identifier.doi | 10.1016/j.enbuild.2011.08.005 | en_US |
dc.dept.handle | 123456789/141 | en |
dc.relation.issue | 11 | en_US |
dc.relation.volume | 43 | en_US |
cut.common.academicyear | 2011-2012 | en_US |
dc.identifier.spage | 3099 | en_US |
dc.identifier.epage | 3105 | en_US |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.openairetype | article | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
crisitem.journal.journalissn | 0378-7788 | - |
crisitem.journal.publisher | Elsevier | - |
crisitem.author.dept | Department of Mechanical Engineering and Materials Science and Engineering | - |
crisitem.author.dept | Department of Mechanical Engineering and Materials Science and Engineering | - |
crisitem.author.faculty | Faculty of Engineering and Technology | - |
crisitem.author.faculty | Faculty of Engineering and Technology | - |
crisitem.author.orcid | 0000-0002-2245-5431 | - |
crisitem.author.orcid | 0000-0002-4497-0602 | - |
crisitem.author.parentorg | Faculty of Engineering and Technology | - |
crisitem.author.parentorg | Faculty of Engineering and Technology | - |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
47
checked on Nov 9, 2023
WEB OF SCIENCETM
Citations
20
39
Last Week
0
0
Last month
0
0
checked on Oct 29, 2023
Page view(s)
567
Last Week
1
1
Last month
3
3
checked on Feb 3, 2025
Google ScholarTM
Check
Altmetric
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.