Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/4269
DC FieldValueLanguage
dc.contributor.authorKasparis, Takis-
dc.contributor.authorPapakyriakou, Pavlos-
dc.contributor.authorChristodoulou, Lakis-
dc.contributor.otherΚασπαρής, Τάκης-
dc.contributor.otherΧριστοδούλου, Λάκης-
dc.date.accessioned2013-02-13T12:32:15Zen
dc.date.accessioned2013-05-17T10:38:27Z-
dc.date.accessioned2015-12-09T12:04:15Z-
dc.date.available2013-02-13T12:32:15Zen
dc.date.available2013-05-17T10:38:27Z-
dc.date.available2015-12-09T12:04:15Z-
dc.date.issued2012-11-
dc.identifier.citation12th International Conference on BioInformatics and BioEngineering, 2012, pp. 500-505en_US
dc.identifier.isbn978-146734358-9-
dc.identifier.urihttps://hdl.handle.net/20.500.14279/4269-
dc.description.abstractThe correct identification of the intima-media thickness (IMT) of the common carotid artery (CCA) walls has a high clinical relevance as it represents one of the most reliable predictor for future cardiovascular events. In this work we propose and evaluate an integrated system for the segmentation of the intima-media complex (IMC) and the lumen diameter in longitudinal ultrasound video of the CCA based on normalization, speckle reduction filtering (with a first order statistics filter) and snakes segmentation. The algorithm is initialized in the first video frame of the cardiac cycle by an automated initialization procedure and the borders of the far wall and near wall of the CCA are estimated. The IMC and the carotid diameter are then segmented automatically in the consecutive video frames for one cardiac cycle. The proposed algorithm was evaluated on 10 longitudinal ultrasound B-mode videos of the CCA and is compared with the manual tracings of a neurovascular expert, for every 20 frames in a time span of 3-5 seconds, covering in general 1-2 cardiac cycles. The algorithm estimated an IMTmean± standard deviation of (0.72±0.22) mm while the manual results were (0.70±0.19). The mean maximum and minimum diameter was (7.08±1.37) mm and (6.53±1.13) mm respectively. The results were validated based on statistical measures and univariate statistical analysis. It was shown that there was no significant difference between the snakes segmentation measurements and the manual measurements. The proposed integrated system could successfully segment the IMC in ultrasound CCA video sequences thus complementing manual measurements.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.rights© 2012 IEEEen_US
dc.subjectCarotid arteryen_US
dc.subjectFilters and filtrationen_US
dc.subjectAlgorithmsen_US
dc.subjectCardiovascular systemen_US
dc.titleVideo segmentation of the common carotid artery intima media complexen_US
dc.typeConference Papersen_US
dc.collaborationCyprus University of Technologyen_US
dc.subject.categoryMedical Engineeringen_US
dc.countryCyprusen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.relation.conferenceIEEE International Conference on Bioinformatics and Bioengineeringen_US
dc.identifier.doi10.1109/BIBE.2012.6399728en_US
dc.dept.handle123456789/134en
cut.common.academicyear2012-2013en_US
item.languageiso639-1en-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairetypeconferenceObject-
item.openairecristypehttp://purl.org/coar/resource_type/c_c94f-
crisitem.author.deptDepartment of Electrical Engineering, Computer Engineering and Informatics-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-3486-538x-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation
CORE Recommender
Show simple item record

SCOPUSTM   
Citations 50

6
checked on Nov 8, 2023

Page view(s) 50

401
Last Week
1
Last month
4
checked on Oct 4, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.