Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/4259
Τίτλος: Polymer PCF Bragg grating sensors based on poly(methyl methacrylate) and TOPAS cyclic olefin copolymer
Συγγραφείς: Kalli, Kyriacos 
Webb, David J. 
Johnson, Ian P. 
Yuan, Wu 
Stefani, Alessio 
Nielsen, Kristian Fog Og 
Rasmussenc, Henrik K. 
Bang, Ole 
metadata.dc.contributor.other: Καλλή, Κυριάκος
Major Field of Science: Engineering and Technology
Field Category: Industrial Biotechnology
Λέξεις-κλειδιά: Bragg gratings;Cadmium;Copolymers;Crystal whiskers;Esters;Fibers
Ημερομηνία Έκδοσης: Απρ-2011
Πηγή: (2011) Proceedings of SPIE - The International Society for Optical Engineering, 8073, art. no. 80732V; Optical Sensors 2011; and Photonic Crystal Fibers V; Prague; Czech Republic; 18 April 2011 through 20 April 2011
Conference: SPIE Optics + Optoelectronics 
Περίληψη: Fibre Bragg grating (FBG) sensors have been fabricated in polymer photonic crystal fibre (PCF). Results are presented using two different types of polymer optical fibre (POF); first multimode PCF with a core diameter of 50μm based on poly(methyl methacrylate) (PMMA) and second, endlessly single mode PCF with a core diameter of 6μm based on TOPAS cyclic olefin copolymer. Bragg grating inscription was achieved using a 30mW continuous wave 325nm helium cadmium laser. Both TOPAS and PMMA fibre have a large attenuation of around 1dB/cm in the 1550nm spectral region, limiting fibre lengths to no longer than 10cm. However, both have improved attenuation of under 10dB/m in the 800nm spectral region, thus allowing for fibre lengths to be much longer. The focus of current research is to utilise the increased fibre length, widening the range of sensor applications. The Bragg wavelength shift of a grating fabricated in PMMA fibre at 827nm has been monitored whilst the POF is thermally annealed at 80 °C for 7 hours. The large length of POF enables real time monitoring of the grating, which demonstrates a permanent negative Bragg wavelength shift of 24nm during the 7 hours. This creates the possibility to manufacture multiplexed Bragg sensors in POF using a single phase mask in the UV inscription manufacturing. TOPAS holds certain advantages over PMMA including a much lower affinity for water, this should allow for the elimination of cross-sensitivity to humidity when monitoring temperature changes or axial strain, which is a significant concern when using PMMA fibre.
ISBN: 978-081948663-9
ISSN: 0277-786X
DOI: 10.1117/12.890090
Rights: © 2011 SPIE.
Type: Conference Papers
Affiliation: Aston University 
Cyprus University of Technology 
Tech University Denmark 
Εμφανίζεται στις συλλογές:Κεφάλαια βιβλίων/Book chapters

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations 50

13
checked on 6 Νοε 2023

Page view(s) 50

349
Last Week
3
Last month
11
checked on 12 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα