Title: Preliminary near wall hemodynamic evaluation of a coronary artery bypass graft model with a flow streamlining implant
Authors: Pedroso, Pedro D. 
Hershey, Bradley L. 
Anayiotos, Andreas 
metadata.dc.contributor.other: Αναγιωτός, Ανδρέας
Keywords: Coronary artery bypass;Hemodynamics;Surgeons
Issue Date: 2002
Source: ASME International Mechanical Engineering Congress and Exposition Proceedings, 2002, Pages 271-272
Abstract: Coronary artery disease (CAD) is the leading cause of death in the world today. According to the American Heart Association 529,659 people in 1999 died as a result of CAD [1]. Starting in the 1960’s, surgeons have used Coronary Artery Bypass Graft (CABG) techniques in order to reestablish blood flow to the heart. Today, the procedure remains the same, using autologous grafts, such as the mammary artery and the saphenous vein. An unresolved problem, is that a significant number of CABGs reocclude months to years postoperatively. In the case of Saphenous Vein Grafts (SVGs) typically 50% of these bypasses are totally occluded months to years after the procedure, the remaining half being more than 50% occluded [2]. The re-occlusion of CABGs is due to a process labeled intimal hyperplasia (IH). Investigators have shown that IH, believed by some to be a remodeling process, occurs at branch sites, regions of curvature, and anastomotic junctions [3,4]. At these sites there are low residence times, slow secondary structures, disturbed flow, and areas of recirculation, therefore the onset of IH is believed to be hemodynamically linked. Most recently, floor IH has been attributed to four variables: time averaged wall shear stress (WSS), oscillating shear index (OSI), spatial wall shear stress gradients (WSSG), and temporal WSSG [5]. Adverse values of these parameters, in the case of SVGs, are believed to be caused by impedance mismatch at the anastomosis site. Over time this characteristic causes a bulge at the sinus. Such a morphology additionally contributes to disturbed flows which tend to propagate down the CABG and are believed to play a major role in the development of IH and the eventual failure of the graft.
URI: https://hdl.handle.net/20.500.14279/3054
ISBN: 0791836509
Rights: © 2002 ASME
Type: Book Chapter
Affiliation: University of Alabama at Birmingham 
Appears in Collections:Κεφάλαια βιβλίων/Book chapters

CORE Recommender
Show full item record

Page view(s) 50

475
Last Week
0
Last month
3
checked on Oct 5, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.