Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/29077
DC FieldValueLanguage
dc.contributor.authorKapnisis, Konstantinos-
dc.contributor.authorKokkinidou, Despoina-
dc.contributor.authorWang, Dehzi-
dc.contributor.authorAnderson, Peter G.-
dc.contributor.authorBrott, Brigitta C.-
dc.contributor.authorLemons, Jack E.-
dc.contributor.authorAnayiotos, Andreas-
dc.date.accessioned2023-04-21T09:39:16Z-
dc.date.available2023-04-21T09:39:16Z-
dc.date.issued2022-03-09-
dc.identifier.citation12th International Conference on Materials Science and Engineering – BraMat, 2022. 9 - 12 March, Brașov, Romaniaen_US
dc.identifier.urihttps://hdl.handle.net/20.500.14279/29077-
dc.description.abstractMedical device materials contain chemicals that pose toxicological problems if released in sufficient quantities in the body. Toxicological risk assessment and prevention by manufacturers include metal surface treatments, in vitro extraction testing and animal experiments to minimize the potential for patients to be exposed to chemicals that may possibly leach out of device materials. Stent retrieval studies by us and others [1.2.3] have shown significant corrosion and leaching of device materials into the body with significant concern by the FDA in numerous recent reports [3,4]. To investigate the peri-implant tissue response to stent biocorrosion, custom made self-expanding nitinol stents (0.7 x 3.3 mm), were implanted in the common carotid artery of male CD1 mice (Project license: CY/EXP/PR.L9/2019). Non-corroded (electropolished) and corroded (heat treated) stents were pre- and post-implantation examined using SEM and also evaluated for Ni ion release (quantified via ICP-MS) in a 60-day immersion test in PBS. Sham-stented samples were also prepared to control for any non-stent related inflammatory effects such as endothelial layer damage caused during catheter guidance. Mice were euthanized under anesthesia at 4 and 8 weeks after surgery and harvested tissue samples were perfusion fixed in situ with 4% PFA for histological analysis which included stent-tissue interaction, thrombus formation, inflammation, and the presence of neointima. A separate group of operated mice was also prepared for nickel ion quantification in peri-implant tissue (dissolved in NaOH and analyzed via ICP-MS). Right before euthanasia, whole blood samples were collected, in citrate prefilled syringes using the cardiac puncture technique, for hematological analysis. Our results indicate that stent surface condition and implantation time affect the development and extent of neointima. The hematological and histological data revealed a significant increase in inflammatory cells, thrombus formation and mature neointima in corroded stented aortas with respect to the electropolished stented aortas. Elevated metal particle contamination, prompted by corroded stents, triggers an inflammatory response. Further studies are warranted to systematically characterize this mechanism that may lead to the development of in-stent restenosis.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.rightsCC0 1.0 Universalen_US
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/*
dc.subjectBiocorrosionen_US
dc.subjectStentsen_US
dc.subjectMetal implantsen_US
dc.titleClinical importance of biocorrosion of metal implants - experimentation and modelingen_US
dc.typeConference Papersen_US
dc.collaborationCyprus University of Technologyen_US
dc.collaborationUniversity of Alabama at Birminghamen_US
dc.subject.categoryMaterials Engineeringen_US
dc.countryCyprusen_US
dc.countryUnited Statesen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.relation.conferenceInternational Conference on Materials Science & Engineering – BraMaten_US
cut.common.academicyear2021-2022en_US
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_c94f-
item.openairetypeconferenceObject-
item.languageiso639-1en-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0002-4999-0231-
crisitem.author.orcid0000-0003-4471-7604-
crisitem.author.parentorgFaculty of Engineering and Technology-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation
Files in This Item:
File Description SizeFormat
BraMat2022 abstract.pdf225.26 kBAdobe PDFView/Open
CORE Recommender
Show simple item record

Page view(s)

158
Last Week
1
Last month
11
checked on May 11, 2024

Download(s) 20

44
checked on May 11, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons