Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/26548
Title: Biocorrosion and biomechanical analysis of explant devices
Authors: Kapnisis, Konstantinos 
Halwani, Dina O. 
Anderson, Peter G. 
Brott, Brigitta C. 
Lemons, Jack E. 
Anayiotos, Andreas 
Major Field of Science: Engineering and Technology
Field Category: Materials Engineering
Keywords: Stents undergo corrosion
Issue Date: 26-Mar-2011
Source: 9ο Κοινό Κύπρο-Ελλαδικό Καρδιολογικό Συνέδριο, 2011, 26-27 Μαρτίου, Λεμεσός, Κύπρος
Conference: Κοινό Κύπρο-Ελλαδικό Καρδιολογικό Συνέδριο 
Abstract: Introduction: Preliminary studies have revealed that stents undergo corrosion in vivo, with significant release of metallic ions into surrounding tissues. It is believed that high concentrations of metal ions from stents are toxic to vascular smooth muscle cells and stimulate both inflammatory and fibrotic reactions leading to neointimal formation and a predisposition to device failure. To separate the mechanical effects from the local environmental effects on the stent surface, in-vitro mechanical studies were performed on various combinations of stents under low and high curvature and in overlapping positions to compare the results of surface corrosion with the explanted stents. Materials and Methods: Accelerated biomechanical studies were performed on Stainless Steel (SS), Nickel Titanium (NiTi) and Cobalt-Chromium (CoCr) stents using Bose®ElectroForce®9110 Stent/Graft mechanical testing instrument. The tested stents underwent surface evaluation by Scanning Electron Microscope (SEM) to identify locations of pitting, fretting and cracking phenomena due to interfacial conditions. Results: Wear features were observed on mechanically tested stents, in single and overlapping cases, in both straight and curved modes. Surface alterations predominantly due to fretting had occurred in the overlapping cases where we observed localized fret features in the areas where there is significant crossing of the wire from both stents. Crevices and fractures were observed in the presence of geometric curvature. Discussion and conclusion: Wear features from cadaver specimens were similar to the surface alterations from some of the mechanical studies. The key finding was that mechanical factors such as arterial curvature combined with stent overlapping enhanced surface alterations, increased the corroded regions and the degree of corrosion in comparison to the single stent-straight artery configuration. The effect of metal corrosion on the arterial wall, the vascular responses and possible cause-effect relationships for biological reactions leading to restenosis are unknown and need further investigation.
URI: https://hdl.handle.net/20.500.14279/26548
Type: Conference Papers
Affiliation : Cyprus University of Technology 
University of Alabama at Birmingham 
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

Files in This Item:
File Description SizeFormat
Περίληψη.pdf98.28 kBAdobe PDFView/Open
CORE Recommender
Show full item record

Page view(s)

243
Last Week
4
Last month
28
checked on Apr 27, 2024

Download(s) 50

31
checked on Apr 27, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons