Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/24338
DC FieldValueLanguage
dc.contributor.advisorChristodoulides, Paul-
dc.contributor.advisorKalogirou, Soteris A.-
dc.contributor.authorArgyrou, Maria C.-
dc.date.accessioned2022-02-18T09:26:28Z-
dc.date.available2022-02-18T09:26:28Z-
dc.date.issued2021-06-
dc.identifier.urihttps://hdl.handle.net/20.500.14279/24338-
dc.description.abstractThe increasing penetration of renewable energy technologies causes major problems in the power network, as their generation cannot be totally predicted. Along with fluctuations in Renewable Energy Sources (RES) production due to weather uncertainties, storage is very important for mitigating several problems that may arise, affecting the stability and reliability of the grid. Thus, storage technologies have gained an increased attention in recent years. In particular, there has been an emphasis on residential storage applications (behind-the-meter storage), with the aim of increasing the energy self-consumption and therefore reducing electricity bills. A model containing a 3 kWp rooftop solar photovoltaic (PV) system connected to the grid through converters and a battery-supercapacitor hybrid energy storage system is proposed. The storage devices are connected to the common 400 V DC-bus in a fully active parallel configuration through two bidirectional DC-DC converters. This configuration allows the battery and supercapacitor to have different voltages and their power flow to be controlled separately. A small-signal stability analysis is considered for the design of the current controllers for both the bidirectional converters of the battery and supercapacitor. Moreover, the small-signal stability analysis of the voltage source inverter (VSI) is considered in order to design the DC-bus voltage controller, from which a reference output current is extracted using a phase-locked loop (PLL) for grid synchronization. A new filtration-based power management algorithm (PMA) is proposed, which prioritizes the utilization of the PVs and battery-supercapacitor instead of the grid, thus increasing the self-consumption and self-sufficiency of the building. A comparison between a battery-only and a battery-supercapacitor storage application is performed in long-term operation (24 hours), verifying the effectiveness of the integration of the supercapacitor. In addition, the dynamic performance of the proposed model is verified through several simulations for different scenarios over short time periods (10–30 seconds). The results show that the model works properly and responds extremely fast during different mode transitions, exhibiting a fast DC-bus voltage regulation with a very low ripple voltage (a maximum of ± 0.625%). Also, the supercapacitor handles rapid changes that occur within 0.2 seconds, which can relieve the battery stress and, hence, extend the battery lifetime. Finally, an effective power sharing is achieved between the PV, the battery-supercapacitor storage, the building load and the grid. The proposed model is developed and simulated in the MATLAB/Simulink software environment, based on mathematical analysis and average modeling.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.rightsΑπαγορεύεται η δημοσίευση ή αναπαραγωγή, ηλεκτρονική ή άλλη χωρίς τη γραπτή συγκατάθεση του δημιουργού και κάτοχου των πνευματικών δικαιωμάτων.en_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectGrid-connected photovoltaicsen_US
dc.subjectBatteryen_US
dc.subjectSupercapacitoren_US
dc.subjectHybrid energy storageen_US
dc.subjectModelingen_US
dc.subjectControlen_US
dc.subjectFiltration-based power managementen_US
dc.titleGrid-connected photovoltaic system in buildings with hybrid energy storageen_US
dc.typePhD Thesisen_US
dc.affiliationCyprus University of Technologyen_US
dc.relation.deptDepartment of Electrical Engineering, Computer Engineering and Informaticsen_US
dc.description.statusCompleteden_US
cut.common.academicyear2020-2021en_US
dc.relation.facultyFaculty of Engineering and Technologyen_US
item.openairetypedoctoralThesis-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_db06-
item.grantfulltextopen-
crisitem.author.deptDepartment of Electrical Engineering, Computer Engineering and Informatics-
crisitem.author.deptDepartment of Electrical Engineering, Computer Engineering and Informatics-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0001-9296-4453-
crisitem.author.orcid0000-0002-2229-8798-
crisitem.author.orcid0000-0002-4497-0602-
crisitem.author.parentorgFaculty of Engineering and Technology-
crisitem.author.parentorgFaculty of Engineering and Technology-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Διδακτορικές Διατριβές/ PhD Theses
Files in This Item:
File Description SizeFormat
PhDThesis-Maria-Argyrou-final Abstract.pdfAbstract610.72 kBAdobe PDFView/Open
PhDThesis-Maria-Argyrou-final.pdfFulltext8.94 MBAdobe PDFView/Open
CORE Recommender
Show simple item record

Page view(s) 50

358
Last Week
4
Last month
14
checked on Aug 28, 2024

Download(s)

288
checked on Aug 28, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons