Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/23793
DC FieldValueLanguage
dc.contributor.authorConstantinou, Achilleas-
dc.contributor.authorGhiotto, Francesco-
dc.contributor.authorLam, Koon Fung-
dc.contributor.authorGavriilidis, Asterios-
dc.date.accessioned2022-01-25T08:41:27Z-
dc.date.available2022-01-25T08:41:27Z-
dc.date.issued2014-01-07-
dc.identifier.citationAnalyst, 2014, vol. 139, no. 1, pp. 266-272en_US
dc.identifier.issn13645528-
dc.identifier.urihttps://hdl.handle.net/20.500.14279/23793-
dc.description.abstractStripping of acetone from water utilizing nitrogen as a sweeping gas in co-current flow was conducted in a microfabricated glass/silicon gasliquid contactor. The chip consisted of a microchannel divided into a gas and a liquid chamber by 10 μm diameter micropillars located next to one of the channel walls. The channel length was 35 mm, the channel width was 220 μm and the microchannel depth 100 μm. The micropillars were wetted by the water/acetone solution and formed a 15 μm liquid film between them and the nearest channel wall, leaving a 195 μm gap for gas flow. In addition, acetone stripping was performed in a microchannel membrane contactor, utilizing a hydrophobic PTFE membrane placed between two microstructured acrylic plates. Microchannels for gas and liquid flows were machined in the plates and had a depth of 850 μm and 200 μm respectively. In both contactors the gas/liquid interface was stabilized: in the glass/silicon contactor by the hydrophilic micropillars, while in the PTFE/acrylic one by the hydrophobic membrane. For both contactors separation efficiency was found to increase by increasing the gas/liquid flow rate ratio, but was not affected when increasing the inlet acetone concentration. Separation was more efficient in the microfabricated contactor due to the very thin liquid layer employed.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.relation.ispartofAnalysten_US
dc.rights© The Royal Society of Chemistry.en_US
dc.subjectSilicon-based micro-stripping chipen_US
dc.subjectConventional semi-conductor processingen_US
dc.titleStripping of acetone from water with microfabricated and membrane gas–liquid contactorsen_US
dc.typeArticleen_US
dc.collaborationUniversity College Londonen_US
dc.subject.categoryChemical Sciencesen_US
dc.journalsSubscriptionen_US
dc.countryUnited Kingdomen_US
dc.subject.fieldNatural Sciencesen_US
dc.publicationPeer Revieweden_US
dc.identifier.doi10.1039/c3an00963gen_US
dc.identifier.scopus2-s2.0-84888354558en
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/84888354558en
dc.contributor.orcid#NODATA#en
dc.contributor.orcid#NODATA#en
dc.contributor.orcid#NODATA#en
dc.contributor.orcid#NODATA#en
dc.relation.issue1en_US
dc.relation.volume139en_US
cut.common.academicyear2013-2014en_US
dc.identifier.spage266en_US
dc.identifier.epage272en_US
item.grantfulltextnone-
item.openairetypearticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.languageiso639-1en-
crisitem.author.deptDepartment of Chemical Engineering-
crisitem.author.facultyFaculty of Geotechnical Sciences and Environmental Management-
crisitem.author.orcid0000-0002-7763-9481-
crisitem.author.parentorgFaculty of Geotechnical Sciences and Environmental Management-
crisitem.journal.journalissn1364-5528-
crisitem.journal.publisherRoyal Society of Chemistry-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

SCOPUSTM   
Citations

21
checked on Mar 14, 2024

WEB OF SCIENCETM
Citations

18
Last Week
0
Last month
0
checked on Oct 29, 2023

Page view(s)

241
Last Week
0
Last month
4
checked on Oct 20, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.