Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/23744
Title: Efficiency and Design Aspects of Ground Heat Exchangers: A Parametric Analysis
Authors: Pouloupatis, Panayiotis 
Christodoulides, Paul 
Aresti, Lazaros 
Messaritis, Vassilios 
Tassou, Savvas A. 
Florides, Georgios A. 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Keywords: Ground Heat Exchanger;Ground Thermal Properties;Geothermal Energy
Issue Date: 2021
Source: 8th International Conference on "Energy, Sustainability and Climate Crisis", Volos, Greece, August 30 - September 3, 2021
Conference: 8th International Conference on "Energy, Sustainability and Climate Crisis" 
Abstract: Shallow Geothermal Energy, a Renewable Energy Source, finds through Ground Heat Exchangers (GHEs) of various configurations (mainly vertical U-tubes, but also horizontal or spiral) that extract or reject heat from / into the ground. The sizing and consequently the cost of such systems (GHEs in conjunction with Ground Source Heat Pumps – GSHPs) depend on various factors. The objective here is to examine the factors affecting the sizing and positioning of GHEs in the Mediterranean environment of Cyprus. There is indeed a large number of parameters involved in the design of such systems, and the desired result can be achieved in various ways depending on the considered parameters. This is done through simulations by commercial design software programs (e.g. GLD) in combination with test data. The parametric study investigates the influence on the performance of GHEs of: (a) the temperature, (b) thermal conductivity, specific heat and density of the ground, (c) pipe diameter (of the GHE). Another important factor studied is the long-term temperature variation of the ground around the GHE boreholes, which affects the positioning of the GHEs. The main outcome of the parametric analysis is that – generally speaking – Cyprus constitutes a proper environment for the application of GSHP/GHE systems. The performance of the GSHP is not affected by the ambient conditions as the ground temperature remains unchanged.
URI: https://hdl.handle.net/20.500.14279/23744
Rights: Attribution-NonCommercial-NoDerivatives 4.0 International
Type: Conference Papers
Affiliation : Cyprus University of Technology 
Brunel University 
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

Files in This Item:
File Description SizeFormat
2021 Pouloupatis et al. ESCC.pdf238.78 kBAdobe PDFView/Open
CORE Recommender
Show full item record

Page view(s)

270
Last Week
0
Last month
4
checked on Dec 22, 2024

Download(s) 50

62
checked on Dec 22, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons