Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/23653
Title: Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filtering
Authors: Loizou, Christos P. 
Pattichis, Constantinos S. 
Pantziaris, Marios 
Tyllis, Theodosis H. 
Nicolaides, Andrew N. 
Major Field of Science: Engineering and Technology
Field Category: Medical Engineering
Keywords: Image quality;Speckle reduction filtering;Ultrasound imaging;Texture analysis;Carotid artery
Issue Date: 2006
Source: Medical & Biological Engineering & Computing, 2006, vol. 44, no. 5, pp. 414–426
Volume: 44
Issue: 5
Start page: 414
End page: 426
Journal: Medical & Biological Engineering & Computing 
Abstract: Image quality is important when evaluating ultrasound images of the carotid for the assessment of the degree of atherosclerotic disease, or when transferring images through a telemedicine channel, and/or in other image processing tasks. The objective of this study was to investigate the usefulness of image quality evaluation based on image quality metrics and visual perception, in ultrasound imaging of the carotid artery after normalization and speckle reduction filtering. Image quality was evaluated based on statistical and texture features, image quality evaluation metrics, and visual perception evaluation made by two experts. These were computed on 80 longitudinal ultrasound images of the carotid bifurcation recorded from two different ultrasound scanners, the HDI ATL-3000 and the HDI ATL-5000 scanner, before (NF) and after (DS) speckle reduction filtering, after normalization (N), and after normalization and speckle reduction filtering (NDS). The results of this study showed that: (1) the normalized speckle reduction, NDS, images were rated visually better on both scanners; (2) the NDS images showed better statistical and texture analysis results on both scanners; (3) better image quality evaluation results were obtained between the original (NF) and normalized (N) images, i.e. NF-N, for both scanners, followed by the NF-DS images for the ATL HDI-5000 scanner and the NF-DS on the HDI ATL-3000 scanner; (4) the ATL HDI-5000 scanner images have considerable higher entropy than the ATL HDI-3000 scanner and thus more information content. However, based on the visual evaluation by the two experts, both scanners were rated similarly. The above findings are also in agreement with the visual perception evaluation, carried out by the two vascular experts. The results of this study showed that ultrasound image normalization and speckle reduction filtering are important preprocessing steps favoring image quality, and should be further investigated.
URI: https://hdl.handle.net/20.500.14279/23653
ISSN: 17410444
DOI: 10.1007/s11517-006-0045-1
Rights: © Springer
Type: Article
Affiliation : Intercollege 
University of Cyprus 
Cyprus Institute of Neurology and Genetics 
Imperial College London 
Saint Mary’s Hospital 
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

SCOPUSTM   
Citations

96
checked on Feb 2, 2024

WEB OF SCIENCETM
Citations

75
Last Week
0
Last month
1
checked on Oct 29, 2023

Page view(s)

235
Last Week
3
Last month
26
checked on Apr 27, 2024

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons