Title: A fully automated method using active contours for the evaluation of the intima-media thickness in carotid US images
Authors: Petroudi, Styliani H. 
Loizou, Christos P. 
Pantziaris, Marios 
Pattichis, Marios S. 
Pattichis, Constantinos S. 
Major Field of Science: Engineering and Technology
Field Category: Medical Engineering
Keywords: Image segmentation;Active contours;Level set;Image edge detection;Ultrasonic imaging;Atherosclerosis;Media
Issue Date: 2011
Source: Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011, 30 August-3 September, Boston, MA, USA
Start page: 8053
End page: 8057
Conference: Annual International Conference of the IEEE Engineering in Medicine and Biology Society 
Abstract: The thickness of the intima-media complex (IMC) of the common carotid artery (CCA) wall is important in the evaluation of the risk for the development of atherosclerosis. This paper presents a fully automated algorithm for the segmentation of the IMC. The segmentation of the IMC of the CCA wall is important for the evaluation of the intima media thickness (IMT) on B-mode ultrasound images. The presented algorithm is based on active contours and active contours without edges. It begins with image normalization, followed by speckle removal. The level set formulation of Chan and Vese using random initialization provides a segmentation of the CCA ultrasound (US) images into different distinct regions, one of which corresponds to the carotid wall region above the lumen whilst another corresponds to the carotid wall region below the lumen and includes the IMC. The results of the corresponding segmentation combined with anatomical information provide a very accurate outline of the lumen-intima boundary. This outline serves as an excellent initialization for segmentation of the IMC using parametric active contours. The method lends itself to the development of a fully automated method for the delineation of the IMC. The mean and standard deviation of the thickness of the automatically segmented regions are 0.65 mm +/-0.17 mm and the corresponding values for the ground truth IMT are 0.66 mm +/-0.18 mm. The Wilcoxon rank sum test shows no significant difference.
URI: https://hdl.handle.net/20.500.14279/23613
ISBN: 978-1-4577-1589-1
DOI: 10.1109/IEMBS.2011.6091986
Rights: © IEEE
Type: Conference Papers
Affiliation : University of Cyprus 
Intercollege 
Cyprus Institute of Neurology and Genetics 
University of New Mexico 
Publication Type: Peer Reviewed
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

CORE Recommender
Show full item record

SCOPUSTM   
Citations 50

15
checked on Feb 1, 2024

Page view(s)

244
Last Week
0
Last month
4
checked on Dec 3, 2024

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons