Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/19403
Τίτλος: | Digital camera calibration for cultural heritage documentation: the case study of a mass digitization project of religious monuments in Cyprus | Συγγραφείς: | Evagorou, Evagoras S. Mettas, Christodoulos Agapiou, Athos Themistocleous, Kyriacos Papavasileiou, Spyridon Hadjimitsis, Diofantos G. |
Major Field of Science: | Natural Sciences | Field Category: | Computer and Information Sciences | Λέξεις-κλειδιά: | Camera calibration;Cultural heritage;Lens distortion;Pre-calibration;Self-calibration | Ημερομηνία Έκδοσης: | 2021 | Πηγή: | European Journal of Remote Sensing, 2021, vol. 54, no. s1, pp. 6-17 | Volume: | 54 | Issue: | s1 | Start page: | 6 | End page: | 17 | Project: | ERATOSTHENES: Excellence Research Centre for Earth Surveillance and Space-Based Monitoring of the Environment | Περιοδικό: | European journal of remote sensing | Περίληψη: | The paper summarizes the methodology followed, to evaluate the accuracy of different digitization methods of ecclesiastical monuments in 3D computer vision form and stresses the importance of photographic equipment calibration. In this study, a set of images were taken using the CANON EOS M5 digital camera, while the internal calibration parameters–horizontal and vertical focal length (fx, fy), principal point coordinates (x0, y0), radial distortion coefficients (K1, K2, K3), tangential distortion coefficients (P1, P2) and the affinity and the shear terms (b1, b2) were estimated. These parameters were calculated using different software applications and then analyzed. For the calibration procedure, 3D texture models were built with the Agisoft commercial software based on: (a) the aforementioned calibration parameters and (b) the self-calibration process. The overall accuracy (Root Mean Square–RMS) between these models, by comparing known geo-referenced ground-control-points (GCP) is presented through the Cloud Compare software. The results indicate that the internal calibration parameters of the digital camera used for documentation purposes are essential and should be systematically implemented for documentation purposes. | URI: | https://hdl.handle.net/20.500.14279/19403 | ISSN: | 2279-7254 | DOI: | 10.1080/22797254.2020.1810131 | Rights: | © The Author(s). | Type: | Article | Affiliation: | Cyprus University of Technology ERATOSTHENES Centre of Excellence Holy Bishopric of Limassol |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Publications under the auspices of the EXCELSIOR H2020 Teaming Project/ERATOSTHENES Centre of Excellence |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
Digital camera calibration for cultural heritage documentation the case study of a mass digitization project of religious monuments in Cyprus.pdf | Fulltext | 14.25 MB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
3
checked on 6 Νοε 2023
WEB OF SCIENCETM
Citations
3
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s) 50
365
Last Week
0
0
Last month
3
3
checked on 22 Δεκ 2024
Download(s)
232
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons