Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/1754
Πεδίο DC | Τιμή | Γλώσσα |
---|---|---|
dc.contributor.author | Demetriou, Themos | - |
dc.contributor.author | Chrysostomou, Christis | - |
dc.contributor.author | Stassis, Andreas | - |
dc.date.accessioned | 2013-03-04T10:52:05Z | en |
dc.date.accessioned | 2013-05-17T05:22:13Z | - |
dc.date.accessioned | 2015-12-02T09:54:33Z | - |
dc.date.available | 2013-03-04T10:52:05Z | en |
dc.date.available | 2013-05-17T05:22:13Z | - |
dc.date.available | 2015-12-02T09:54:33Z | - |
dc.date.issued | 2005 | - |
dc.identifier.citation | Structural Control and Health Monitoring, 2005, vol. 12, no. 2, pp.197-212 | en_US |
dc.identifier.issn | 15452255 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.14279/1754 | - |
dc.description.abstract | The church of Agios Ioannis Prodromos in the village of Askas, Cyprus, contains a vast cycle of important and rare Byzantine wall paintings dating from the 15th and 16th centuries. Because of its importance to the cultural heritage of Cyprus, the church has been selected as one of the monuments to be studied in an INCO-MED project for the Conservation of Historical Mediterranean sites by innovative seismic protection techniques (CHIME). The computational model developed for the church is presented, as well as the measurements obtained by hammer-impact excitation. The fine-tuning of the selected computational model to match the dynamic characteristics obtained from the site measurements is also discussed. The model was used to test analytically the cost-effectiveness of damping devices in providing the best earthquake protection to the church without spoiling its monumental value. | en_US |
dc.format | en_US | |
dc.language.iso | en | en_US |
dc.relation.ispartof | Structural Control and Health Monitoring | en_US |
dc.rights | © John Wiley & Sons | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | Earthquake engineering | en_US |
dc.subject | Monuments | en_US |
dc.subject | System identification | en_US |
dc.title | Retrofit of a church with linear viscous dampers | en_US |
dc.type | Article | en_US |
dc.collaboration | Higher Technical Institute Cyprus | en_US |
dc.journals | Hybrid Open Access | en_US |
dc.country | Cyprus | en_US |
dc.subject.field | Engineering and Technology | en_US |
dc.publication | Peer Reviewed | en_US |
dc.identifier.doi | 10.1002/stc.56 | en_US |
dc.dept.handle | 123456789/54 | en |
dc.relation.issue | 2 | en_US |
dc.relation.volume | 12 | en_US |
cut.common.academicyear | 2005-2006 | en_US |
dc.identifier.spage | 197 | en_US |
dc.identifier.epage | 212 | en_US |
item.fulltext | No Fulltext | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.cerifentitytype | Publications | - |
item.openairetype | article | - |
crisitem.journal.journalissn | 1545-2263 | - |
crisitem.journal.publisher | Wiley | - |
crisitem.author.dept | Department of Civil Engineering and Geomatics | - |
crisitem.author.dept | Department of Mechanical Engineering and Materials Science and Engineering | - |
crisitem.author.faculty | Faculty of Engineering and Technology | - |
crisitem.author.faculty | Faculty of Engineering and Technology | - |
crisitem.author.orcid | 0000-0002-7141-7423 | - |
crisitem.author.orcid | 0000-0002-9755-1444 | - |
crisitem.author.parentorg | Faculty of Engineering and Technology | - |
crisitem.author.parentorg | Faculty of Engineering and Technology | - |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
17
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
11
Last Week
0
0
Last month
0
0
checked on 27 Οκτ 2023
Page view(s)
531
Last Week
1
1
Last month
31
31
checked on 13 Μαρ 2025
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons