Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/1690
DC FieldValueLanguage
dc.contributor.authorMyers, Jerry G.en
dc.contributor.authorPerry, Gilbert J.en
dc.contributor.authorAnayiotos, Andreas-
dc.contributor.otherΑναγιωτός, Ανδρέας-
dc.date.accessioned2013-03-04T13:58:16Zen
dc.date.accessioned2013-05-17T05:22:18Z-
dc.date.accessioned2015-12-02T09:56:48Z-
dc.date.available2013-03-04T13:58:16Zen
dc.date.available2013-05-17T05:22:18Z-
dc.date.available2015-12-02T09:56:48Z-
dc.date.issued1996en
dc.identifier.citationAmerican Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1996, Volume 33, Pages 281-282en
dc.identifier.issn10716947en
dc.identifier.urihttps://hdl.handle.net/20.500.14279/1690-
dc.description.abstractThe steady normalized centerline-velocity distribution proximal to an orifice has been used in quantifying valvular regurgitation with color Doppler (CD). However, the presence of pulsitility and constraining walls in a viscous flowfield may influence the centerline flow characteristics. This study utilized computational fluid dynamic (CFD) models of the flow region proximal to an axisymmetric orifice to investigate the combined effects of adjacent wall influence and time dependence on the proximal flowfield. Steady state conditions and time waveforms for flowrate and pressure-gradient were used as input boundary conditions. Results of this study indicate that normalized centerline velocity distributions depend on adjacent wall orientation. However, for a specific wall orientation, the instantaneous, normalized, centerline-velocity distribution showed little deviation from steady state distributions. These results suggest that the steady state proximal centerline velocity distribution is a good approximation the pulsatile centerline distribution for a specific time.en
dc.formatpdfen
dc.language.isoenen
dc.rights© ASMEen
dc.subjectBlood-vesselsen
dc.subjectHemodynamicsen
dc.subjectComputer simulationen
dc.titleTime dependent characteristics of valvular regurgitation: A numerical investigationen
dc.typeArticleen
dc.affiliationUniversity of Alabama at Birminghamen
dc.dept.handle123456789/54en
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairetypearticle-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-4471-7604-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

Page view(s) 50

372
Last Week
0
Last month
3
checked on Dec 22, 2024

Google ScholarTM

Check


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.