Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/1679
DC FieldValueLanguage
dc.contributor.authorBrott, Brigitta C.-
dc.contributor.authorChapman, Gregory D.-
dc.contributor.authorAnayiotos, Andreas-
dc.contributor.otherΑναγιωτός, Ανδρέας-
dc.date.accessioned2013-03-04T10:33:51Zen
dc.date.accessioned2013-05-17T05:22:12Z-
dc.date.accessioned2015-12-02T09:56:14Z-
dc.date.available2013-03-04T10:33:51Zen
dc.date.available2013-05-17T05:22:12Z-
dc.date.available2015-12-02T09:56:14Z-
dc.date.issued2006-12-
dc.identifier.citationJournal of Invasive Cardiology, 2006, vol. 18, no. 12, pp. 584-592en_US
dc.identifier.issn10423931-
dc.identifier.urihttps://hdl.handle.net/20.500.14279/1679-
dc.description.abstractOBJECTIVES: Three cases of severe, diffuse coronary artery spasm after drug-eluting stent placement at our institution prompted this review. BACKGROUND: Drug-eluting stents have gained widespread use due to extraordinarily low rates of restenosis. Despite these generally superior clinical outcomes, the specter of rare idiosyncratic reactions remains a concern. METHODS: We performed searches of Medline and the U.S. FDA Manufacturer And User facility Device Experience database (MAUDE) to identify and describe spasm after coronary stent placement. Searches included drug-eluting and bare-metal stents. Institutional cases are reviewed. Location, time course and outcome of cases are described. RESULTS: Thirteen cases of spasm were identified after stent placement. Seven cases occurred after Cypher™ drug-eluting stent placement, 2 after Taxus® drug-eluting stent placement, 1 after BiodivYsio™ and 3 after bare-metal stents. Five patients experienced diffuse, multivessel spasm, 2 after Cypher, 2 after Taxus, and 1 after a Velocity™ stent. Of these 5 patients, 2 died. An additional 2 required intra-aortic balloon pump placement for cardiogenic shock. Another had persistent symptomatic, diffuse coronary spasm documented by angiography at 1 year. CONCLUSIONS: We describe coronary spasm after stent placement, particularly after drug-eluting stents. Outcomes associated with diffuse severe spasm after stenting are poor, and the pathophysiology remains poorly understood.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.relation.ispartofJournal of Invasive Cardiologyen_US
dc.rights© HMPen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectNitroglycerinen_US
dc.subjectHeparinen_US
dc.subjectAngiocardiographyen_US
dc.subjectCoronary arteryen_US
dc.titleSevere, diffuse coronary artery spasm after drug-eluting stent placementen_US
dc.typeArticleen_US
dc.affiliationUniversity of Alabama at Birminghamen
dc.collaborationUniversity of Alabama at Birminghamen_US
dc.journalsOpen Accessen_US
dc.countryCyprusen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.dept.handle123456789/54en
dc.relation.issue12en_US
dc.relation.volume18en_US
cut.common.academicyear2006-2007en_US
dc.identifier.spage584en_US
dc.identifier.epage592en_US
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairetypearticle-
crisitem.journal.journalissn1042-3931-
crisitem.journal.publisherH M P Communications-
crisitem.author.deptDepartment of Mechanical Engineering and Materials Science and Engineering-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-4471-7604-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

Page view(s) 50

388
Last Week
2
Last month
10
checked on Dec 22, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons