Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/1674
Title: | Modeling aqueous humor collection from the human eye | Authors: | Kapnisis, Konstantinos Doormaal, Mark Van Ross Ethier, C. |
Major Field of Science: | Engineering and Technology | Field Category: | Other Engineering and Technologies | Keywords: | Glaucoma;Anterior chamber;Posterior chamber;Aqueous humor fluid;Drainage angle;Navier–Stokes equations;Finite elements | Issue Date: | 13-Nov-2009 | Source: | Journal of Biomechanics, 2009, vol. 42, no. 15, pp. 2454-2457 | Volume: | 42 | Issue: | 15 | Start page: | 2454 | End page: | 2457 | Journal: | Journal of Biomechanics | Abstract: | Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatially non-uniform in the eye, and thus the composition of the aspirated fluid is uncertain. Our goal was to numerically simulate the AH aspiration process to determine where the aspirated fluid was being collected from and thus gain insight into the composition of the collected fluid. A 3D computational model of the anterior region of the human eye was created and the Navier-Stokes equations were numerically solved during the aspiration process for a set of typical (baseline) conditions: 40 μl aspirated volume and needle placement in the central anterior chamber. We also ran variations of this baseline simulation. The main finding was that the aspirated fluid comes from a very localized region around the needle tip, so that for typical conditions, almost no aspirated fluid is withdrawn from the angle region of the anterior chamber. This is important because the AH in this angle region is protein-rich and directly interacts with the tissues that control fluid drainage from the eye. Recommendations for standardizing aspiration conditions are given. | URI: | https://hdl.handle.net/20.500.14279/1674 | ISSN: | 00219290 | DOI: | 10.1016/j.jbiomech.2009.07.025 | Rights: | © Elsevier | Type: | Article | Affiliation: | Imperial College London | Affiliation : | Imperial College London | Publication Type: | Peer Reviewed |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
21
checked on Nov 9, 2023
WEB OF SCIENCETM
Citations
18
Last Week
0
0
Last month
0
0
checked on Oct 28, 2023
Page view(s) 20
465
Last Week
0
0
Last month
1
1
checked on Dec 26, 2024
Google ScholarTM
Check
Altmetric
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.